Page 1
Safety. Use only with UL Listed Portable Air Sampling Pump Battery Pack. Made by 1000 112th Circle N, Suite 100 • St. Petersburg, Florida 33716 USA (800) 451-9444 • (727) 530-3602 • (727) 539-0550 [FAX] • www.sensidyne.com REF F-PRO-1725 (G)
Page 3
LFS-113 LOW FLOW AIR SAMPLING PUMP OPERATION MANUAL FLOW ADJ Made in USA Patent Pending Dual Mode LOW FLOW SAMPLER Model LFS-113DC TIME (MIN) Personal Air Sampler LISTED 17G9 ® MODEL LFS-113D / LFS-113DC Intrinsically Safe Portable Air Sampling Pump for use in hazardous locations: Class I Groups A,B,C,D;...
PROPRIETARY NOTICE This manual was prepared exclusively for the owner of the Sensidyne LFS-113 Low Flow Air Sampling Pump. The mate- rial within this manual is proprietary information and is to be used only to understand, operate, and service the instrument.
• Appendix B: Specifications ....................17 • Appendix C: Service ......................18 LIST OF FIGURES LFS-113 Air Sampling Pump: Front View ..............8 LFS-113 Air Sampling Pump: Rear View ..............9 Field Calibration Equipment Set-Up ............... 10 Field Calibration: Constant Flow ................12 Field Calibration: Multi-Flow ..................
DO NOT operate this product should it malfunction, require repair, or have a cracked or broken case. DO NOT repair or modify, except as specified in Operation Manual. No user servicable parts located within case. Service to be performed by Sensidyne Authorized Service Departments only.
SECTION ONE INTRODUCTION • COMPONENTS • See Figures 1.1 and 1.2 (1) Inlet Boss (9) Discharge (Bag Sampling) Boss The Inlet Boss is located on the filter housing and This is an accessory which, when installed into provides a built-in means of attaching tubing for the Outlet Port, provides a means for filling air suction sampling.
LFS-113 LOW FLOW AIR SAMPLING PUMP Made in USA FLOW ADJ Patent Pending Dual Mode LOW FLOW SAMPLER Model LFS-113DC TIME (MIN) Personal Air Sampler LISTED 17G9 ® MODEL LFS-113D / LFS-113DC Intrinsically Safe Portable Air Sampling Pump for use in hazardous locations: Class I Groups A,B,C,D;...
SECTION TWO PUMP OPERATION 2.1 Equipment Set-Up 1) Use an LFS-113 pump with a fully charged battery pack. 2) Attach tubing to the pump. 3) Connect a constant flow [3A] or Multi-Flow [3B] collection device to the tubing. 4) Connect the tubing from the collection device to a Gilibrator 2.
LFS-113 LOW FLOW AIR SAMPLING PUMP 2.2 Field Calibration/Flow Verification Field calibration (flow rate verification) must be per- 5) Turn on the pump using a pointed instrument formed before sampling and when setting the flow such as ball point pen [5].
LFS-113 LOW FLOW AIR SAMPLING PUMP UNIVERSAL TUBE HOLDER SYSTEM (THH-L-240) Patent Pending Made in USA Made in USA FLOW ADJ Patent Pending Dual Mode LOW FLOW SAMPLER Model LFS-113DC TIME (MIN) Personal Air Sampler LISTED 17G9 ® MODEL LFS-113D / LFS-113DC Intrinsically Safe Portable Air Sampling Pump for use in hazardous locations: Class I Groups A,B,C,D;...
LFS-113 LOW FLOW AIR SAMPLING PUMP UNIVERSAL TUBE HOLDER SYSTEM (THH-L-240) Patent Pending Made in USA UNIVERSAL TUBE HOLDER SYSTEM (THH-L-240) Patent Pending Made in USA Made in USA FLOW ADJ Patent Pending Dual Mode LOW FLOW SAMPLER Model LFS-113DC...
LFS-113 LOW FLOW AIR SAMPLING PUMP 2.3 Taking A Sample 1) Use a pointed instrument such as a ball point pen to turn on the pump. 2) Place the pump, tubing and sampling device on the worker as shown in Figure 2.4.
A constant-rate single-station charger that is suitable for both overnight charging and weekend charging. The LFS-113 pump uses rechargeable Nickel-Cadmium LFATR Multi-Station Charger batteries that must be fully charged and properly A dual rate charger offering five-station timed maintained for maximum run time.
800093-3 ..... Filter Assembly (pkg of 3) Spare Parts Part Number Description 400324 ......5-Unit Charger, 120V 298-0005-01 ....Single Unit Charger, 120V 800222 ......Tool Kit 800685 ......Air Boss Kit (required for bag sampling) F-PRO-1725 ....LFS-113 Manual REF F-PRO-1725 (G)
APPENDIX C SERVICE Domestic Service Sensidyne, LP 1000 112th Circle N, Suite 100 St. Petersburg, Florida 33716 USA 800-451-9444 727-530-3602 727-539-0550 [Main fax] 727-538-0671 [Service fax] e-mail: info@sensidyne.com web: www.sensidyne.com REF F-PRO-1725 (G)
Page 20
Manufactured by: Sensidyne, LP 1000 112th Circle N, Suite 100 St. Petersburg, Florida 33716 800-451-9444 • 727-530-3602 • 727-539-0550 [fax] www.sensidyne.com • info@sensidyne.com...
Need help?
Do you have a question about the LFS-113 and is the answer not in the manual?
Questions and answers