Sensidyne LFS-113 Operation Manual

Low flow air sampling pump
Hide thumbs Also See for LFS-113:

Advertisement

Quick Links

LFS-113 LOW FLOW
AIR SAMPLING PUMP
OPERATION MANUAL
1000 112th Circle N, Suite 100 • St. Petersburg, Florida 33716 USA
(800) 451-9444 • (727) 530-3602 • (727) 539-0550 [FAX] • www.sensidyne.com
FLOW ADJ
Made in USA
Dual Mode
LOW FLOW SAMPLER
Model LFS-113DC
TIME (MIN)
Personal Air Sampler
LISTED 17G9
®
MODEL LFS-113D / LFS-113DC
Intrinsically Safe Portable Air Sampling Pump for use in
hazardous locations: Class I Groups A,B,C,D; Class II
Groups E,F,G; Class III. Temperature Code T3C.
WARNING
Substitution of components may impair Intrinsic
Safety. Use only with UL Listed Portable Air
Sampling Pump Battery Pack.
Made by
REF F-PRO-1725 (G)
Patent Pending
B
ON
F
OFF

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LFS-113 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sensidyne LFS-113

  • Page 1 Safety. Use only with UL Listed Portable Air Sampling Pump Battery Pack. Made by 1000 112th Circle N, Suite 100 • St. Petersburg, Florida 33716 USA (800) 451-9444 • (727) 530-3602 • (727) 539-0550 [FAX] • www.sensidyne.com REF F-PRO-1725 (G)
  • Page 3 LFS-113 LOW FLOW AIR SAMPLING PUMP OPERATION MANUAL FLOW ADJ Made in USA Patent Pending Dual Mode LOW FLOW SAMPLER Model LFS-113DC TIME (MIN) Personal Air Sampler LISTED 17G9 ® MODEL LFS-113D / LFS-113DC Intrinsically Safe Portable Air Sampling Pump for use in hazardous locations: Class I Groups A,B,C,D;...
  • Page 4: Notices

    PROPRIETARY NOTICE This manual was prepared exclusively for the owner of the Sensidyne LFS-113 Low Flow Air Sampling Pump. The mate- rial within this manual is proprietary information and is to be used only to understand, operate, and service the instrument.
  • Page 5: Table Of Contents

    • Appendix B: Specifications ....................17 • Appendix C: Service ......................18 LIST OF FIGURES LFS-113 Air Sampling Pump: Front View ..............8 LFS-113 Air Sampling Pump: Rear View ..............9 Field Calibration Equipment Set-Up ............... 10 Field Calibration: Constant Flow ................12 Field Calibration: Multi-Flow ..................
  • Page 6: Warnings

    DO NOT operate this product should it malfunction, require repair, or have a cracked or broken case. DO NOT repair or modify, except as specified in Operation Manual. No user servicable parts located within case. Service to be performed by Sensidyne Authorized Service Departments only.
  • Page 7: Components

    SECTION ONE INTRODUCTION • COMPONENTS • See Figures 1.1 and 1.2 (1) Inlet Boss (9) Discharge (Bag Sampling) Boss The Inlet Boss is located on the filter housing and This is an accessory which, when installed into provides a built-in means of attaching tubing for the Outlet Port, provides a means for filling air suction sampling.
  • Page 8: Lfs-113 Air Sampling Pump: Front View

    LFS-113 LOW FLOW AIR SAMPLING PUMP Made in USA FLOW ADJ Patent Pending Dual Mode LOW FLOW SAMPLER Model LFS-113DC TIME (MIN) Personal Air Sampler LISTED 17G9 ® MODEL LFS-113D / LFS-113DC Intrinsically Safe Portable Air Sampling Pump for use in hazardous locations: Class I Groups A,B,C,D;...
  • Page 9: Lfs-113 Air Sampling Pump: Rear View

    LFS-113 LOW FLOW AIR SAMPLING PUMP Figure 1.2 LFS-113 Air Sampling Pump: Rear View REF F-PRO-1725 (G)
  • Page 10: Equipment Set-Up

    SECTION TWO PUMP OPERATION 2.1 Equipment Set-Up 1) Use an LFS-113 pump with a fully charged battery pack. 2) Attach tubing to the pump. 3) Connect a constant flow [3A] or Multi-Flow [3B] collection device to the tubing. 4) Connect the tubing from the collection device to a Gilibrator 2.
  • Page 11: Field Calibration/Flow Verification

    LFS-113 LOW FLOW AIR SAMPLING PUMP 2.2 Field Calibration/Flow Verification Field calibration (flow rate verification) must be per- 5) Turn on the pump using a pointed instrument formed before sampling and when setting the flow such as ball point pen [5].
  • Page 12: Field Calibration: Constant Flow

    LFS-113 LOW FLOW AIR SAMPLING PUMP UNIVERSAL TUBE HOLDER SYSTEM (THH-L-240) Patent Pending Made in USA Made in USA FLOW ADJ Patent Pending Dual Mode LOW FLOW SAMPLER Model LFS-113DC TIME (MIN) Personal Air Sampler LISTED 17G9 ® MODEL LFS-113D / LFS-113DC Intrinsically Safe Portable Air Sampling Pump for use in hazardous locations: Class I Groups A,B,C,D;...
  • Page 13: Field Calibration: Multi-Flow

    LFS-113 LOW FLOW AIR SAMPLING PUMP UNIVERSAL TUBE HOLDER SYSTEM (THH-L-240) Patent Pending Made in USA UNIVERSAL TUBE HOLDER SYSTEM (THH-L-240) Patent Pending Made in USA Made in USA FLOW ADJ Patent Pending Dual Mode LOW FLOW SAMPLER Model LFS-113DC...
  • Page 14: Taking A Sample

    LFS-113 LOW FLOW AIR SAMPLING PUMP 2.3 Taking A Sample 1) Use a pointed instrument such as a ball point pen to turn on the pump. 2) Place the pump, tubing and sampling device on the worker as shown in Figure 2.4.
  • Page 15: Battery Maintenance

    A constant-rate single-station charger that is suitable for both overnight charging and weekend charging. The LFS-113 pump uses rechargeable Nickel-Cadmium LFATR Multi-Station Charger batteries that must be fully charged and properly A dual rate charger offering five-station timed maintained for maximum run time.
  • Page 16: Appendix Aparts List

    800093-3 ..... Filter Assembly (pkg of 3) Spare Parts Part Number Description 400324 ......5-Unit Charger, 120V 298-0005-01 ....Single Unit Charger, 120V 800222 ......Tool Kit 800685 ......Air Boss Kit (required for bag sampling) F-PRO-1725 ....LFS-113 Manual REF F-PRO-1725 (G)
  • Page 17: Appendix B: Specifications

    APPENDIX B SPECIFICATIONS Additional Features ........Flow Fault indication LED Batt check LED Belt clip Dual filtration system Sorbent tube end breaker External flow adjust Options ............Elapsed timer clock module (DC models only): LCD display automatic instant-fault shutdown function RFI shielding Dimensions ...........
  • Page 18: Appendix C: Service

    APPENDIX C SERVICE Domestic Service Sensidyne, LP 1000 112th Circle N, Suite 100 St. Petersburg, Florida 33716 USA 800-451-9444 727-530-3602 727-539-0550 [Main fax] 727-538-0671 [Service fax] e-mail: info@sensidyne.com web: www.sensidyne.com REF F-PRO-1725 (G)
  • Page 20 Manufactured by: Sensidyne, LP 1000 112th Circle N, Suite 100 St. Petersburg, Florida 33716 800-451-9444 • 727-530-3602 • 727-539-0550 [fax] www.sensidyne.com • info@sensidyne.com...

Table of Contents