DIP Switch Settings and Functions
DIP Switch and Function
DIP Switch 1
If selected, displays a status code or displays a status code
and causes shutdown if the pressure imbalance exceeds
selection made in DIP Switch 2.
DIP Switch 2
Select pressure imbalance limits, that if exceeded, will cause
a deviation and a shutdown (if enabled).
DIP Switch 3
If selected, causes shutdown or displays a status code due
to deviation of pressure from setpoint exceeds selection
made in DIP Switch 4.
DIP Switch 4
Causes deviation if pressure setpoint is greater than:
DIP Switch 5
Causes shutdown or displays a status code for low fluid level
in tanks.
DIP Switch 6
Enables or disables boost heat.
DIP Switch 7
DIP Switch 8
*
Default DIP Switch Settings
DIP Switch 1 and 2 Settings
DIP Switch
DIP Switch
2
1
Off
Off
*
Off
On
*
Off
On
*
*
On
On
332144H
DIP Switch Settings and Functions
Deviation
Shutdown
300 psi (2.1
---
MPa, 21 bar)
500 psi (3.5
---
MPa, 35 bar)
300 psi (2.1
500 psi (3.5
MPa, 21 bar)
MPa, 35 bar)
500 psi (3.5
800 psi (5.6
MPa, 35 bar)
MPa, 56 bar)
OFF
DEVIATION
See Dip Switch 1 and 2 Settings table, page 31
DEVIATION
300 psi (2.1 MPa, 21
bar)
(25% if < 800 psi [5.6
MPa, 56 bar])
*DEVIATION
DISABLE
Not used
Not used
Troubleshooting
ON
DEVIATION AND
SHUTDOWN
*SHUTDOWN
*500 psi (3.5 MPa, 35
bar)
(40% if < 800 psi [5.6
MPa, 56 bar])
SHUTDOWN
*ENABLE
31