Locate Reactor

Locate the Reactor on a level surface.
NOTE: Do not expose the Reactor to rain.

Electrical Requirements

Improper wiring may cause electric shock or other
serious injury if work is not performed properly. All
electrical wiring must be done by a qualified
electrician and comply with all local codes and
regulations.
1. Connect the Reactor to the correct power source for
your model. See T
ABLE
connected to two separate, dedicated circuits. See
F
. 4.
IG
2. Some models include cord adapters for use outside
North America. Connect the appropriate adapter to
the unit's power cord before connecting to your
power source.
Model
200-240VAC, 1 phase,
50/60 Hz, two 15 ft
(4.5 m) power cords
100-120VAC, 50/60
Hz, two 15 ft (4.5 m)
power cords
Model
All models
Cords must be 3-conductor grounded, rated for your environment.
16
4. Power cords must be
Table 4: Electrical Requirements
Required Power Source
Two separate, dedicated
circuits rated at minimum
of 15 A each
Two separate dedicated
circuits rated at minimum
of 20 A each
Table 5: Extension Cord Requirements
To avoid electric shock, always unplug both cords
before servicing the Reactor and wait one minute.
Heater Power
1
1
Ensure no other high amp loads are connected while running
Reactor.
2
To verify separate circuits, plug in Reactor or a worklight and
cycle breakers on and off.
F
. 4 Use Two Separate Circuits
IG
Power Cord
Connectors
Supplied Local Adapters
Two IEC 3-20 C20
Plugs
Two NEMA
5-20P Plugs
Required Wire Size
Up to 50 ft (15 m)
AWG 12
1
Motor Power
NEMA 6-15P
(North America)
Euro CEE74
(Europe)
(Australia/Asia)
YP-39 AS3112
Up to 100 ft (30 m)
AWG 10
2
TI7061a