Media; Replacing A Damaged Tapping Valve - Viega 9690TW Instructions For Use Manual

Geopress tapping valve. for water applications
Table of Contents

Advertisement

Potable water installation
2.2.2

Media

2.2.3

Replacing a damaged tapping valve

Geopress tapping valve
For planning, execution and operation of potable water house service
connections, observe the applicable regulations, see
from section: Fields of application' on page 5.
The max. operating pressure depends on the type of pipe used and the
specific application.
Potable water / Class A Recycled Water
Operating pressure p
n
max
CAUTION!
A hole must be drilled in accordance with
'Tapping the supply line' on page 20 to make a tight con‐
nection. The tapping valve must not be positioned at the
location of an existing hole. When a Viega tapping valve is
replaced, the new tapping valve must not be placed in the
position of the previously dismounted tapping valve.
Failure to comply may cause a leak in the connection to
the supply line.
= 1600 kPa (16 bar)
Product information
Ä 'Regulations
Ä Chapter 3.4.3
7