Removing Top Shroud; Replacing Fender; Controls; Replacing Power Module - Invacare TDX SP2 Series Service Manual

Hide thumbs Also See for TDX SP2 Series:
Table of Contents

Advertisement

Invacare® TDX® SP2 Series
TDX SP2 Low-Rider is equipped with a water
protection flap under the rear shroud. The
illustrations below does not show it.
Fig. 6-29
Removing Rear Shroud
1. Loosen and remove hand screw I on rear shroud G.
2. Carefully loosen rear shroud. Pay attention to cable
of operating hour counter.
3. Take note of positions of cables and sockets. Mark
plugs and sockets or take a photo with digital camera.
4. Remove cable of operating hour counter from drive
motor.
5. Remove rear shroud.
6. If installed, remove water protection flap.
Installing Rear Shroud
1. Install parts in reverse order.
2. Tighten all screws finger-tight.

6.9.4 Removing top shroud

Size 2 Phillips screwdriver
Removing top shroud
1. Remove seat.
2. Undo the four Phillips screws B on the top shroud A.
3. Remove top shroud.
Installing top shroud
1. Install parts in reverse order.
2. Tighten all screws finger-tight.
42

6.9.5 Replacing fender

6 mm Allen key
Two long wooden blocks, min. 14 x 14 x 30 cm
Torque wrench 0 - 20 Nm (or similar)
Torque wrench 5 - 25 Nm (or similar)
Flat screwdriver
Fig. 6-30
Removing fender
1. Remove drive wheel as described in 6.8.8 Replacing
Drive Wheel (5–Screw Installation), page 38.
2. Loosen and remove three slotted screws B.
3. Remove fender A from walking beam.
Installing fender
1. Install parts in reverse order.
2. Tighten screws to 4.5 Nm.

6.10 Controls

6.10.1 Replacing Power Module

Various power modules can be installed to the mobility
device with a range of different remotes.
CAUTION!
Any changes to drive program can affect
driving characteristics and tipping stability of
mobility device
– Changes to drive program may only be carried
out by trained providers.
– Invacare can only give a warranty for safe
mobility device driving behavior - especially
tipping stability - for unaltered standard drive
programs.
All power modules are delivered with a
standard drive program. If you have carried
out customer-specific modifications to the drive
program, you will have to repeat these changes
after installing the new power module.
For replacement of remote in combination with
power module and the subsequent selection of
LiNX drive programs, see below.
For DX, ACS or ACS 2 electronic module, see earlier
revision of this Service manual.
To adapt drive program: Programming software
or hand programming device and system
installation manual, available from Invacare.