THROUGH THE WALL - DIRECT VENT INSTALLATION
NOTE: THE CHIMNEY SHOULD EXTEND AT LEAST 3'
ABOVE THE HIGHEST SIDE OF THE ROOF OPENING
AND BE AT LEAST 2' HIGHER THAN ANY PORTION
OF THE BUILDING WITHIN 10' HORIZONTALLY.
10" ALL
FUEL SMOKE
EXTRACTOR
CHIMNEY
The oven's minimum clearances from combustible materials are 18" on left side, 24" on right, 18" on top, 48"
from front, and 2" on back. Minimum clearances are 18" to chimney connector and to smoke extractor chimney
connector. Floor may be constructed of a combustible material. (Note: minimum clearance dimensions are from the
oven cabinet, not from component cover.) (If provision is made for access to service, minimum clearance can be
reduced to 2" on left side.) May be installed through a combustible wall with zero clearance with BBR kit No. 2099.
ANY VENTILATION SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES. CONSULT WITH
LOCAL OFFICIALS AND A COMMERCIAL KITCHEN VENTILATION CONTRACTOR PRIOR TO INSTALLATION.
Southern Pride Distributing, L.L.C.
2102 East Main Street - Marion, Illinois 62959
www.southern-pride.com
Sales: 800-851-8180
VENTING INSTALLATION
RAIN
6"
CAP
ALL FUEL
CHIMNEY
(*) ONLY
THE SMOKE
EXTRACTOR
DAMPER AND
ADAPTER
PLATE ARE
SUPPLIED BY
SOUTHERN
PRIDE.
sales@sopride.com
XLR-1600-4-SL
N
OTE 1. When installing an Oven through a
wall constructed of combustible material, use
the Southern Pride Insulation Kit between
the oven and the wall.
2. The room that the face of the oven is installed
into should have a balanced or positive air pressure.
If the room has negative air pressure, smoke could
escape into the room during operation.
SUPPLIED BY SOUTHERN PRIDE: (*)
Smoke Extractor Damper with 10" chimney adapter plate
SUPPLIED BY CUSTOMER:
6" All Fuel Chimney, 6" Rain Cap, and all accessories
necessary for installation of the 6" chimney. All Fuel
Chimney, Exhaust Fan (NOTE: Fan must be listed for
use as a commercial kitchen ventilator), fan curb, and
all accessories necessary for installation of the smoke
extractor system.