VSP HOOD SYSTEM:
VSP HOODS are U/L Listed to the applicable
Southern Pride oven models and are NSF Certified.
HOOD SYSTEM TO INCLUDE:
1. Ventilation Hood
2. Two speed fan (1380/2000)
3. Curb with vented extension and hinge kit
(Specify roof pitch)
4. Grease capture trough
5. Combustion chamber flue vent
SUPPLIED BY CUSTOMER:
6. Duct from hood to fan
NOTE: If you have a duct longer than 10 feet or an elbow in your duct your
installation, it may require a larger capacity exhaust fan. Please specify your
duct requirements when ordering the VSP Hood System.
ALL MODELS MAY ALSO BE INSTALLED UNDER A CANOPY
HOOD RATED FOR COMMERCIAL COOKING APPLIANCES.
N O TE :
TH E S I X I NC H A L L F U EL C H IM N E Y
S H O U L D EX T EN D A T LE A S T 3 ' A B O V E T HE
H IG H E S T S ID E O F T H E R O O F O P EN IN G
A N D B E A T L E AS T 2 ' H IG H E R T H A N A N Y
P O R TI O N O F T H E B U I LD I N G W I TH IN 1 0 '.
H O R IZ ON TA L .
6 " A LL
F U EL
C H IM N E Y
EX H A U S T
F A N
NOTE: THE 10 " ALL
FUEL SMOKE EX-
TRACTOR CHIMNEY
T ERMIN ATES AT
THE ROOF C URB
1 0 " A L L F U EL S M O K E
E X TR A C T OR CH IM N E Y
The oven's minimum clearances from combustible materials are 18" on left side, 24" on right, 18" on top, 48"
from front, and 2" on back. Minimum clearances are 18" to chimney connector and to smoke extractor chimney
connector. Floor may be constructed of a combustible material. (Note: minimum clearance dimensions are from the
oven cabinet, not from component cover.) (If provision is made for access to service, minimum clearance can be
reduced to 2" on left side.) May be installed through a combustible wall with zero clearance with BBR kit No. 2099.
ANY VENTILATION SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES. CONSULT WITH
LOCAL OFFICIALS AND A COMMERCIAL KITCHEN VENTILATION CONTRACTOR PRIOR TO INSTALLATION.
Southern Pride Distributing, L.L.C.
2102 East Main Street - Marion, Illinois 62959
www.southern-pride.com
Sales: 800-851-8180
VENTING INSTALLATION
Purchased through Southern Pride
1
RA I N
C A P
sales@sopride.com
Service: 800-437-2679
XLR-1400-SL
6
XLR-1400-SL with
recommended optional
VSP Vent Hood System.
THROUGH THE WALL OR
DIRECT VENT INSTALLATION
N
OTE 1. When installing an Oven through a
wall constructed of combustible material, use
the Southern Pride Insulation Kit between
the oven and the wall.
2. The room that the face of the oven is installed
into should have a balanced or positive air pressure.
If the room has negative air pressure, smoke could
escape into the room during operation.
SUPPLIED BY SOUTHERN PRIDE: (*)
Smoke Extractor Damper with 10" chimney adapter plate
SUPPLIED BY CUSTOMER:
6" All Fuel Chimney, 6" Rain Cap, and all accessories
necessary for installation of the 6" chimney.
10" All Fuel Chimney, Exhaust Fan (NOTE: Fan must
be listed for use as a commercial kitchen ventilator),
fan curb, and all accessories necessary for installation
of the smoke extractor system.
service@sopride.com
Service Fax: 618-993-0378
2
4
3
SPECIFY ROOF PITCH
WHEN ORDERING
5
Phone: 618-997-9348
Fax:
618-993-5960
parts@sopride.com
9/1/04

Advertisement

loading