Transfer Outside
Clock data displayed in the GT11 can be transferred to an external device such as a PLC, using this
setting.
• Off:
The GT11 clock data is not transferred to an external device.
• On
The GT11 clock data is transferred to an external device.
If "On" is selected for the above "Transfer Outside" parameter, click on the
output destination and the initial device, and specify the address.
Transfer sequence of clock data
Address
Top address
Top address + 1
Top address + 2
Top address + 3
Note) In the day data, H00 indicates Sunday and H06 indicates Saturday.
Note:
If "On" is selected for the "Transfer Outside" parameter, the data will be transferred to the DT90054 as
the default device. If this device address does not exist in the PLC connected to the GT11, howefver, re-
specify the address so that it matches the model connected to the GT11.
Selecting a device address that does not exist in the PLC will cause an error (ER61) to occur.
Backlight control
Auto-Off
This is used to specify the Auto-Off backlight feature.
• Off:
The Auto-Off backlight feature is not used.
• On:
Auto-Off backlight feature is used. This parameter specifies the period of time that the GT11
is inactive before the backlight goes off automatically.
If "On" is set for the above Auto-Off backlight feature, clicking on the
the time until the backlight goes off can be specified. Any time from one minute to 30 minutes can be
specified.
Key Point:
• If the backlight is turned off automatically using the backlight control function, touching the screen
turns it on again. If a touch switch happens to be located at that point on the screen, it will be invalid
until the backlight has gone on again.
Touch Sounds
This sets the touch sounds corresponding to GT11 screens as either invalid or valid. Select one of the
radio buttons.
• Disable:
Touch sounds are disabled.
• Enable:
Touch sounds are enabled.
Battery Error Display
This specifies whether or not a dead battery mark will be displayed on the GT11 screen if the voltage of
the internal battery drops too low.
• Off:
The dead battery mark ( ) is not displayed.
• On:
The dead battery mark ( ) is displayed.
Upper byte
Minutes data (H00 to H59)
Day data (H01 to H31)
Year data (H00 to H99)
-
button to specify the
Lower byte
Second data (H00 to H59)
Hour data (H00 to H23)
Month data (H01 to H12)
Day data (H00 to H06)