REASSEMBLY, REPAIR AND ADJUSTMENT
FUJICA AX - 1

15. Adjustment of electrical system

Variable resistors VR1 through VR6 are used. Out of these variable resistors, VR1,
VR5 and VR6 have been completely adjusted at the plant.
variable resistors.
Adjust VR2, VR3 and VR4 accurately with DC 5V applied.
provide this voltage.)
- 9 6 -
Do not touch these
(A new battery will