REASSEMBLY, REPAIR AND ADJUSTMENT
FUJICA A X - 1
f.
Install the attracted pieces (5 -149 and 5 -155) with Alonalpha (adhesive)
as described below.
o Wind up the focal plane shutter completely.
o Apply DC 3.5V to
o
Set the release lever (5 -163) to the release position.
o Now, install the attracted pieces with Alonalpha.
CAUTION:
and
magnets.
o Do not apply Alonalpha excessively.
o
Hold the attracted pieces as they are at least 10 seconds
after installing them.
c
Be careful not to allow Alonalpha impregnating into the
attracted surface. Be sure to impregnate Alonalpha between
the attracted piece supporting shaft (5-150, 5-156) and
attracted piece (5 -149, 5 -155).
o To wipe off Alonalpha, use acetone (CH
- 7 4 -
)