Seeley Breezair EXH Series Installation And Operating Instructions Manual page 8

Evaporative air cooler
Table of Contents

Advertisement

The high salinity setting
is designed
to operate
the cooler at a maximum
safe salinity
level to
maintain
a normal working
life. It also results in
a minimum
usage of water.
ILL1106-A
ILL1110-A
NOTE:
High salinity
outlet water should not be
used on salt sensitive
grass or plants.
It has a
high salt content.
The current WaterManager
® setting
is
displayed
by holding
down the E
button and
pressing
the E
button. The setting can be
changed
by holding down the _0F27 button and
pressing
either the _
or ( -v
button for
HI and LO respectively.
The factory
default
WaterManager
® setting
is
H!. For areas operating
with bore water,
DIP
switch F should
be switched
to off (see page
6). This will disable the salinity
measuring
circuit and simply drain water from the tank
every 65 minutes
of operation.
POWER
FAILURE
RECOVERY
After a power disruption
is restored,
the cooler
will automatically
restart within 10 minutes,
if
the remote control
has remained
"ON" during
the power failure.
BATTERIES
If the batteries
are installed
when the display
is
completely
blank, the display will remain
blank
for 5 seconds.
After 5 seconds
the display will
show "ld" for 1 second,
then display the clock.
The remote control is now ready to use.
The remote control requires
3 AAA batteries,
The use of good quality alkaline
batteries
is
recommended,
Under normal
conditions
a set
of batteries
will operate
for 18 months.
Do not use rechargeable
batteries
as their
_e
rating is too low for the remote control.
When the batteries
are getting low on power,
BATTERY
LOW is displayed
on the screen (the
cooler may also switch off while the display
remains
ON). This indicates
that the batteries
have only a small amount of life remaining.
To change
the batteries
remove the cover from
the back of the remote control.
Pull out the old
batteries
and replace
them all with the new
ones. Do not mix new batteries
with old
batteries.
The remote control has 2 minutes
of back-up
power to retain its memory
while the batteries
are being changed.
DIP SWITCHES
There are 2 rows of DIP switches
located
under the battery
cover on the remote
control.
WARNING:
Do not alter
DiP switches
1 to 8
on top row and 7 & 8 on bottom
row as the
cooler
will cease
to work.
1
2345678
ON
1
2345678
°"I
EXAMPLE
ONLY
ILL217-H
Definition
of DIP switch positions
(first 6 in
bottom row only) are as follows:
BOTTOM
ROW
(1) ...... Reserved
for later use.
(2) ...... OFF, 24 hour clock,
ON, 12 hour clock.
(3) ...... Not Used
(4) ...... OFF, no pre-cool.
ON, pre-cool.
(5) ...... OFf
drains 3 days after power off.
ON, drains 3 hours after power off.
(6) ...... OFF, drains
every 65 minutes
of
operation.
ON, activates
water salinity circuit
(WaterManager
_ ).