Seeley Climate Master CM12W Owner's Manual
Seeley Climate Master CM12W Owner's Manual

Seeley Climate Master CM12W Owner's Manual

Portable refrigerated air conditioner

Advertisement

OWNER'S MANUAL
Portable Refrigerated Air Conditioner
Climate Master CM12W, CM12WX, CP12HS,
CM15WX, CM15HW, CP15W, CP15HS
®

Advertisement

Table of Contents
loading

Summary of Contents for Seeley Climate Master CM12W

  • Page 1 OWNER’S MANUAL Portable Refrigerated Air Conditioner Climate Master CM12W, CM12WX, CP12HS, CM15WX, CM15HW, CP15W, CP15HS ®...
  • Page 2: Table Of Contents

    CONTENTS Introduction ........1 Safety ..........2 Component location......3 Installing the exhaust hose ....4 Control panel ........5 Remote control ........6 Operation........7-8 Maintenance ........9 Troubleshooting ......10 Specifications.........11 Warranty ........12 Please read these instructions prior to using the appliance and save them for future reference. Waste electrical products must not be disposed of with household waste.
  • Page 3: Introduction

    Personal Cooling Your Convair cooler is a portable air conditioning unit that supplies refrigerated air to a personal area within a room. It is not intended to function as a house or room air conditioner. SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 4: Safety

    SAFETY Electrical Safety (cont) General Safety For indoor use only. Caution! before connecting the Transport the air conditioner in an electrical power cord to a power outlet, upright position only, or leave it in an check that the air conditioner voltage is upright position for at least 2 hours the same as your power supply (refer to before use (Fig 1).
  • Page 5: Component Location

    Remote Control Rating Label Active Carbon Filter Cord Storage Air Intake Door (active carbon filter to be fitted here) Air Filter Exhaust Air Outlet Power Exhaust Hose Cord Exhaust Fitting Drain (window end) Window Attachment SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 6: Installing The Exhaust Hose

    INSTALLING THE EXHAUST Assembling the exhaust hose (Fig 5,6) Note! The minimum distance required Step 1: Fit the exhaust hose to the rear from the operating air conditioner to panel outlet by rotating the hose in a any obstructing objects or walls is clockwise direction.
  • Page 7: Control Panel

    CP12HS, CP15HS and CM15HW) Set Temperature Water Tank Display Full Indicator Dehumidifying Ion / TiO Indicator Mode Indicator (only models CM12WX and CM15WX) Fan Mode Indicator Fan Speed Indicator Sleep Mode Indicator Medium High Timer Indicator SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 8: Remote Control

    REMOTE CONTROL Signal transmission point Fan speed adjust buttons Mode buttons (Cool-Dehumidify- Fan-Heat) Temperature adjust buttons Sleep mode button Timer on / adjust button Ion / TiO button (only active for Power ON / OFF models CM12WX Battery button and CM15WX) compartment Battery cover Preparation before operation...
  • Page 9: Operation

    DEHUMIDIFYING or FAN modes. Step 5: Press the FAN SPEED button on the control panel or remote control to adjust the fan speed. Each press will cycle the fan speed through low, medium & high. SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 10: Operation

    OPERATION cont. Air Conditioner Features When the air conditioner is OFF (but still plugged in), repeat the above to set the ON time. The air conditioner will start up with the Step 6: Your air conditioner has a SLEEP last settings used. mode, activated by pressing the button on the control panel or remote control.
  • Page 11: Maintenance

    Operate the unit in fan only mode for a few hours, to thoroughly dry the inside. Clean or change the filters. Unplug and carefully store the power cord and plug end behind the cord storage door (Fig 13C). Replace in the original carton or cover for storage. SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 12: Troubleshooting

    TROUBLESHOOTING Problem Check The air conditioner does Is the air conditioner plugged in ? not run. Is there a power failure? Is the "WATER FULL" error code flashing? Drain the tank as shown (Fig 13). Is the room temperature below the set temperature? The air conditioner has little Is there direct sunshine? Remember to close curtains effect (firstly ensure that the...
  • Page 13: Specifications

    SPECIFICATIONS SEELEY INTERNATIONAL - CLIMATEMASTER PORTABLE AIR CONDITIONER CM12W, CM12WX CP12HS CM15WX, CP15W CM15HW, CP15HS Model(s) Function Personal Cooling Personal Cooling & Heating Personal Cooling Personal Cooling & Heating Cooling Capacity (Watts) † 3,500 (12,000 Btu/hr) 3,500 (12,000 Btu/hr) 4,400 (15,000 Btu/hr) 4,400 (15,000 Btu/hr) Heating Capacity (Watts) †...
  • Page 14: Warranty

    WARRANTY In this warranty: or us means Seeley International Pty Ltd ABN 23 054 687 035, and our contact details are set out at the end of this warranty; means you, the original end-user purchaser of the Goods; Supplier means the authorised distributor or retailer of the Goods that sold you the Goods in Australia;...
  • Page 15 CM15WX CM15HW CP15W CP15HS Purchased from ............................Date purchased ../../..Service Department Seeley International Pty Ltd 112 O'Sullivan Beach Road, Lonsdale, South Australia 5160 Customer service centre in Australia: 1300 650 644 Website: www.seeleyinternational.com SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 16 It is the policy of Seeley International to introduce continual product improvement. Accordingly, specifications are subject to change without notice. Please consult with your dealer to confirm the specifications of the model selected. Warranty Service Australia 1-300-650-644 seeleyinternational.com ® convair.net.au...

Table of Contents