module or expansion board.
Local station number and remote network address and station number setting:
The maximum number of slave station PLC that can be connected through the
network is 254 stations; when the module operation is in client mode, in order
to map the local station number (to the main PLC) to the slave station PLC on
the network, the mapping table must first be set when applying this function.
Firmware update function: The Ether_Config software provides the function to
update the CBEH expansion board's firmware. Please refer to Chapter 10 for
detailed operation contents.
External service setting: CBEH provides internet clock synchronization (NTP
Server), SMTP Server, Service Callback Server and DNS Server functions that
require external services which can be set and used according to the user's
needs.
Only Ether_Cfg with version V3.0 or above supports the CBEH module.
The Ether_cfg utility with version before V3.0 is not support CEBH, please first
confirm the software version, or go directly to FATEK's official website to download
the newest Ether_Cfg software to configure CBEH. After opening the software, click
on "About" in the main menu to display the following icon, you can find the version
number behind Version:

3.1.1 Connecting To CBEH Through LAN

When the CBEH and host computer (PC) is connected with local area network (LAN)
and you do not know the CBEH expansion board's network address (IP), you can
execute the Ether_Config software and use the following method to connect to the
CBEH expansion board: