VERDER VERDERFLEX Dura D7 Instruction Manual page 11

Peristaltic industrial hose pump
Table of Contents

Advertisement

Ignition Hazard
Description / Basic
Potential
Cause (which causes
Ignition
originate
Source
which ignition
hazard)
Mechanical
– Rotor failure
strength
– Pump materials incom-
Chemical
patible with pumped
Reaction
media
Table 9 Ignition Protection
ATEX Instruction Manual
Dura 05-55
Measures Applied to Prevent the Ignition Source Becoming Effective
Reason for
Description of the Measure
Assessment
Rotor failure
u Requirement to use motor pro-
causing over
tection relay.
temperature in
u Motors supplied with PTCs.
motor
u End user/ sales applications
Hose burst
engineer to ensure awareness
exposing
of pump construction and
casing to media
compatibility of hose material
with pumped media.
Version 1.0v-07/2019
Basis Citation of
Applied
Technical Rules
EN 80079-36:2016 10
EN 80079-36:2016 10
Standard
11 | Page