Items Relating To The Time Code (Nos. 601 To; Items Relating To The Time Code (Nos. 601 To - Sony SRW-5000 Operation Manual

Hd digital videocassette recorder
Hide thumbs Also See for SRW-5000:
Table of Contents

Advertisement

Items Relating to the Time Code (Nos. 601 to ...)

Item number
Item
601
DF/NDF MODE
select
602
TIMER MODE
select
603
TCR MODE select
604
TC2 MODE SEL
154
Menu List
Setting
Function
[drop frame]
Selects the timing mode for the time code generator and
non-drop frame
the CTL counter.
auto
drop frame: drop frame mode ("DF" indication)
non-drop frame: non-drop frame mode ("NDF" indication)
auto: Drop frame / non-drop frame mode is selected
Notes
• This setting is only active when the frame frequency of
• When the [F7](TCG MODE) key is set to "regene" in TC
CTL
Selects the mode for displaying time data.
[TC]
CTL: During playback the CTL signal recorded on the tape,
UBIT
TC: The time code value read by the time code reader, or
UBIT: The user bits inserted in the playback time code, or
[LTC]
Selects the time code read by the time code reader during
auto
playback.
VITC
LTC: LTC is read.
auto: If the playback speed is in the range ±1/2 normal
VITC: VITC is read.
UBG
Selects the time data appearing in the second line.
TCG
UBG: Displays UBG.
UBV
TCG: Displays TCG.
UBR
UBV: Displays UBV.
CTL
UBR: Displays UBR.
VITC
CTL: Displays CTL.
auto
VITC: Displays VITC.
LTC
auto: Displays VITC when the playback speed is in the
[off]
LTC: Displays LTC.
off: Does not display time data in the second line.
automatically on the basis of the frame frequency of
the unit. For 29.97 Hz drop frame mode is selected,
and for 30 Hz non-drop frame mode is selected. The
setting of the frame frequency mode is carried out with
the [F9](OTHERS CHECK)/ [F9] (SYSTEM) button in
MAINTENANCE menu.
the unit is 29.97 Hz or 30 Hz.
menu, the time code generator is synchronized to the
playback time code, and therefore this setting is disabled.
or during recording the CTL signal being recorded on
the tape, is counted, and the tape running time is
displayed in hours, minutes, seconds, and frames.
the time code value generated by the time code
generator is displayed. Use item 603 to toggle between
VITC and LTC.
the user bits inserted in the time code being recorded
are displayed. Use item 603 to toggle between VITC
and LTC.
speed, VITC is read, and if outside this range LTC is
read.
range ±1/2 normal speed, and LTC if outside this
range.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srw-5500

Table of Contents