3. How to Order
IZD10 - * 10
4. Specification
Electrostatic sensor
model no.
Measuring range
Output voltage
Effective detection
distance
Linearity
Output delay time
Source voltage
Power consumption
Operating ambient
temp.
Operating ambient
humidity
Material
Vibration resistance
Impact resistance
Weight
EN Standard
Applicable Conditions
EMC Directive
*1 : Relation between measuring range and output voltage depends on detection distance.See the chart in
"6-1 Output signal" for the relation between the detected potential and the output voltage based on
detection distance.
5. Mounting
5-1. Electrostatic sensor installation
5-1-1. Sensor head installation
When using the electrostatic sensor, install it to the place where the sensor head detection hole
can detect the object. (See "6-2. Detection range")
[Note ] Pitch between the inspection hole and inspected subject surface depends on sensor
model. Refer [4. Specifications] to avoid the hole from contacting the subject. Charged
potential of inspected subject may be discharged to the sensor head. Keep the subject and
the sensor head apart when installing. Discharge to the sensor head lead to cause damage
of the sensor head. Output signal and detection range depend on installation distance.See
6-1, 6-2.
Use two M3 screws for mounting the sensor head(prepare separately).
Recommended tightening torque for M3 screw : 0.61 to 0.63Nm.
Measuring range
1
+/- 0.4kV
5
+/- 20kV
IZD10-110
+/- 0.4kV
(when detection distance 25mm)
1 to 5V (Output impedance Approx. 100ohms)
10 to 50mm
+/- 5%F.S. (when 0 to 50
distance 25mm)
Resisting 50Hz Fluctuation 1mm XYZ 2hours for each
Protection Class:Class III equipment(according to EN60950-1)
Ce marking:Low Voltage Directive:73/23/EEC,93/68/EEC
Only connect to SELV-type external circuits
89/336/EEC,92/31/EEC,93/68/EEC,2004/108/EC
*1
(when detection distance 50mm)
o
C, detection
+/- 5%F.S. (when 0 to 50
Within 100ms
DC24V +/-10%
40mA or less
o
0 to 50
35 to 85%Rh (No dew formed)
Head case:ABS Amplifier case:ABS
100m/s
185g (Including cable weight)
Environment:Pollution degree 3
7
IZD10-510
+/- 20kV
25 to 75mm
distance 50mm)
C
2
*1
o
C, detection
Need help?