Download Print this page
SMC Networks D-MP Series Instruction Manual

SMC Networks D-MP Series Instruction Manual

Actuator position sensor
Hide thumbs Also See for D-MP Series:

Advertisement

Quick Links

D-MP-SMX03EN
ORIGINAL INSTRUCTIONS
Refer to Declaration of
Conformity for relevant
Instruction Manual
Directives
Actuator Position Sensor
D-MP# series
The intended use of the actuator position sensor is to monitor the position
of the actuator while connected to the IO-Link communication protocol.
1 Safety Instructions
These safety instructions are intended to prevent hazardous situations
and/or equipment damage. These instructions indicate the level of
potential hazard with the labels of "Caution," "Warning" or "Danger."
They are all important notes for safety and must be followed in addition
*1)
to International Standards (ISO/IEC)
, and other safety regulations.
*1)
ISO 4414: Pneumatic fluid power - General rules relating to systems.
ISO 4413: Hydraulic fluid power - General rules relating to systems.
IEC 60204-1: Safety of machinery - Electrical equipment of machines.
(Part 1: General requirements)
ISO 10218-1: Manipulating industrial robots -Safety. etc.
• Refer to product catalogue, Operation Manual and Handling
Precautions for SMC Products for additional information.
• Keep this manual in a safe place for future reference.
• This product is class A equipment intended for use in an industrial
environment. There may be potential difficulties in ensuring
electromagnetic compatibility in other environments due to conducted
or radiated disturbances.
Caution indicates a hazard with a low level of risk which, if
Caution
not avoided, could result in minor or moderate injury.
Warning indicates a hazard with a medium level of risk
Warning
which, if not avoided, could result in death or serious injury.
Danger indicates a hazard with a high level of risk which, if
Danger
not avoided, will result in death or serious injury.
Warning
• Always ensure compliance with relevant safety laws and
standards.
• All work must be carried out in a safe manner by a qualified person in
compliance with applicable national regulations.
• Do not disassemble, modify (including changing the printed
circuit board) or repair.
An injury or failure can result.
• Do not operate the product outside of the specifications.
Fire, malfunction or damage to the product can result.
• Do not operate in an atmosphere containing flammable, explosive
or corrosive gas.
Fire or an explosion can result.
• Do not use the product for flammable or harmful fluids.
Fire, explosion, damage or corrosion can result.
• If using the product in an interlocking circuit:
Provide a double interlocking system, for example a mechanical
system.
• Check the product for correct operation.
Otherwise malfunction can result, causing an accident.
• Do not use the product in a place where static electricity is a
problem.
Product failure or system malfunction may result.
Otherwise electric shock, malfunction or product damage can result.
• Refer
to
the
operation
manual
on
the
SMC
(URL: https://www.smcworld.com) for more safety instructions.
2 Specifications
2.1 General specifications
D-MP
D-MP
Model
025∗
050∗
Length determination
25 mm
50 mm
range
±1 mm
±1 mm
15 to 30 VDC, ripple (p-p) 10% or below
Power supply voltage
(with power supply polarity protection)
Current consumption
48 mA or less (when no load is applied)
Repeatability
0.1 mm (@25
Resolution
0.05 mm
Linearity
±0.3 mm (@25
Switch
NPN or PNP 1 output (push-pull)
output
Max. load
current
Internal
voltage
2 V or less
drop
NPN: 0.5 mA or less at load resistance 3 kΩ,
Leakage
1.5 mA or less at load resistance 750 Ω
current
PNP: 0.1 mA or less
Short
circuit
protection
Output
4 to 20 mA
Analogue
current
current
Max. load
output
resistance
Output
0 to 10 V
Analogue
voltage
voltage
Min. load
output
resistance
PUR 4 core φ2.6 0.08 mm
Lead wire
Standards
CE marked (EMC and RoHS Directive), UL
Impact resistance
300 m/s
Insulation resistance
50 MΩ or more with 500 VDC Ohmmeter
Withstand voltage
1000 VAC 1 minute
Ambient temperature
-10 to 60
Enclosure rating
IEC60529 IP67
2.2 IO-Link specifications
D-MP
D-MP
Model
025∗
050∗
IO-Link type
IO-Link version
SIO mode
Available
Communication
COM3 (230.4 kbps)
speed
Minimum cycle time
Process data length
Input: 2 bytes, Output: 0 bytes
Device ID
125 hex
126 hex
Vendor ID
website
3 Names of Individual parts
3.1 D-MP#
D-MP
D-MP
100∗
200∗
100 mm
200 mm
±1 mm
±1 mm
o
C)
Mounting screw
o
C)
3.2 Operation Display
Indicator light
40 mA
Yes
Operation Light Colours
Blue
500 Ω
Green
2 kΩ
2
Category
Mode
2
Analogue
Current
output
o
C
Analogue
Voltage
output
System
status
IO-Link
D-MP
D-MP
100∗
200∗
Device
V1.1
Error
High
1 ms
Switch
Low
127 hex
128 hex
output
83 hex
Over current
error
In measuring
range
Magnetic
field
Outside of
measuring
range
= LED ON,
= LED flashing, = LED OFF
B = Blue, O = Orange, G = Green
4 Installation
4.1 Installation
• Do not install the product unless the safety instructions have been read
and understood.
Lead wire
• Use the product within the specified operating pressure and
temperature range.
Mounting screw
• When mounting an actuator position sensor, use a mounting bracket
appropriate for the cylinder/actuator.
Operation display
• The mounting method differs according to the type of actuator and the
inner diameter of the tube.
• When mounting a sensor for the first time, check that the
cylinder/actuator has a built-in magnet and use an appropriate bracket
for the cylinder/actuator. There are also cases when a bracket is not
needed.
• Use the correct tightening torque
When tightening mounting screws, use a suitable hexagon wrench
Indicator light
(size 1.5). Recommended torque should be 0.2 to 0.4 Nm.
Over-tightening can damage the cylinder/actuator and sensor.
Loose screws can cause misalignment or a reduction in accuracy
during operation. Tightening below the specified tightening torque will
allow the position sensor to move out of position.
• Do not carry an actuator by the position sensor lead wire.
• This may cause a broken lead wires or damage to the auto switch
Teach pad
internal elements.
• Use only the screws installed in the position sensor body for mounting
the position sensor.
If other screws are used, the position sensor may be damaged.
• Check and adjust the actual product operation during installation.
Blue
The auto switch may not operate in the correct actuator mounting
position due to the installation environment. Also check and adjust the
auto switch operation when used in intermediate stroke positions,
according to the operating environment.
Orange
• Press the switch down into the cylinder/actuator switch mounting
groove as shown.
Indicator
Indicator
Description
light 2
light 1
B
Analogue current
output active
G
Analogue voltage
output active
G
IO-Link connection
• Tighten the mounting screws evenly.
active
O
Sensor not ready for
operation /
Detectable magnetic
field is decrease.
LED flashing at 4 Hz
B
Switch output High
PNP: ON, NPN: OFF
B
Switch output Low
PNP: OFF, NPN: ON
B
Overload of the switch
output (over current)
4.2 Environment
LED flashing.
O
Magnetic field
• Do not use in an environment where corrosive gases, condensation,
registered in
chemicals, salt water or steam are present.
• Do not use in an explosive atmosphere.
measuring range
• Do not expose to direct sunlight. Use a suitable protective cover.
O
Magnetic field is not
• Do not install in a location subject to vibration or impact in excess of
registered in
the product's specifications.
• Do not mount in a location exposed to radiant heat that would result in
measurement range
temperatures in excess of the product's specifications.
• Do not use in a location where magnetic fields are generated.
Warning
Warning
Page 1 of 3

Advertisement

loading
Need help?

Need help?

Do you have a question about the D-MP Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SMC Networks D-MP Series

  • Page 1 D-MP-SMX03EN 2 Specifications 3 Names of Individual parts 4 Installation ORIGINAL INSTRUCTIONS 2.1 General specifications 3.1 D-MP# 4.1 Installation Warning D-MP D-MP D-MP D-MP Refer to Declaration of Model • Do not install the product unless the safety instructions have been read 025∗...
  • Page 2 D-MP-SMX03EN 4 Installation (continued) 5 Setting 4.3 Wiring 5.1 Initial settings 5.3 Teach Level 2 Switch output: Low (NPN = ON, PNP = OFF), Caution Analogue output: Current output, Range: Full range Teach • Do not perform wiring while the power is on. Click and hold Level 2 •...
  • Page 3 D-MP-SMX03EN 6 Maintenance 9 Troubleshooting 6.1 General Maintenance Refer to the operation manual on the SMC website (URL: Caution https://www.smcworld.com) detailed information about troubleshooting. • Not following proper maintenance procedures could cause the product When any position sensor failure occurs, perform the trouble shooting to malfunction and lead to equipment damage.

This manual is also suitable for:

D-mp 050 seriesD-mp 025 seriesD-mp 200 seriesD-mp 100 series