Installation, Servicing and User Instructions for
LD33, LD36, LD38 and LD39 DRY BAINS MARIE
CAUTION: Read the instructions before using the appliance.
Important Installation Information
The installer must ensure that installation of the unit(s) is in conformity with regulations in force at the time.
For the UK, particular attention requires to be paid to:-
BS7671 IEE Wiring Regulations
Electricity at Work Regulations
Health and Safety at Work Act
Fire Precautions Act
The unit has been CE-marked on the basis of compliance with the Low Voltage and EMC Directives for the
voltage stated on the data plate.
WARNING: THIS APPLIANCE MUST BE EARTHED!
Preventive Maintenance Contract
In order to obtain maximum performance from the equipment, we would recommend that a maintenance
contract be arranged with AFE Serviceline.
Visits may then be made at agreed intervals to carry out adjustments and repairs. A quotation for this
service will be provided upon request. Contact AFE Serviceline as detailed below:-
Tel: 01438 363 000
WEEE Directive Registration No. WEE/DC0059TT/PRO
At end of unit life, dispose of appliance and any replacement parts in
a safe manner, via a licenced waste handler. Units are designed to be dismantled
easily and recycling of all material is encouraged whenever practicable.
Falcon Foodservice Equipment
Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland.
LD34, LD37 and LD43 WET BAINS MARIE
Fax: 01438 369 900
T100330 Ref. 3

Advertisement

loading

Summary of Contents for Falcon Pro-Lite LD33

  • Page 1 At end of unit life, dispose of appliance and any replacement parts in a safe manner, via a licenced waste handler. Units are designed to be dismantled easily and recycling of all material is encouraged whenever practicable. Falcon Foodservice Equipment Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland. T100330 Ref. 3...
  • Page 2: Section 1 - Siting

    Technical Installation & Information Table Model Width Depth Height Weight Rating Fuse Rating LD33 Dry Bains Marie 300mm 630mm 285mm 15kg 0.48kW 3 amp LD34 Wet Bains Marie 300mm 630mm 285mm 15kg 1.0kW 5 amp LD36 Dry Bains Marie 450mm 630mm 285mm 18kg...
  • Page 3: Section 3 - Using And Cleaning Pro-Lite Units

    The appliance is also provided with a terminal for the connection of an external equipotential conductor. This terminal is in effective electrical contact with all fixed exposed metal parts of the appliance, and shall allow the connection of a conductor having a nominal cross-sectional area of up to 10 mm².
  • Page 4: Section 4 - Servicing

    The LD33, LD34, LD36 and LD37 are supplied with 4.5 litre pots. The LD38, LD39 and LD43 models accommodate a mix of gastronorm containers and bridging bars are provided as standard. Containers are supplied. The LD39 and LD43 models are designed to hold 1/4 and 1/2 size gastronorm trays. The LD38 is supplied with 3 x 1/4 gastronorm trays and lids.
  • Page 5 Elements Remove access panel. Undo electrical connections, noting positions. Undo element fixings and remove. Replace in reverse order. Terminal Block Remove base plate. Remove electrical connections at terminal block, noting positions. Undo fixings that secure block to unit and remove. Replace in reverse order.
  • Page 6 LD33, 36, 38 7 39 DRY BAINS MARIE WIRING DIAGRAM...