Description Of The Function Code - Lenze 7812 Technical Description

Inverter drives
Table of Contents

Advertisement

ET46/ffa
checked: 19.04.89
7.3 Description of the tiinction code
Function code 00
The display can be prograznined after mains switch—on mains using
thls function code.
Data code
00: Display ot the rotational fieid frequency
01: Display of the motor current (R.~4.S.).
By pressing the SHIFT-key, either frequency or current display can ~e
selected
during operation.
Functiori code 01, 02, 03
The inverter is set to one
tield frequencies, by olosing the switches S3 and/or S4. As soon
as S3 and/or S4 are closed, any other set—value setting is
made inactive.
S3
closed
open
closed
Function code 04
The inverter is set to a fourth, programined rotational ffield
frequency by closing switch S5. As soon as S5 is closed,
any other set-value setting, as well as switches 53 and S4 are
inactive. The frequency is set in Hz. (Factory setting is 5 Hz).
Note:
At maximum ffrequencies higher than 50 or 60Hz, the rotational
field treguencies which are set
03 and 04 are multiplied according
:Or example-
Maximum frequency: 150Hz
(Function code 10 data code 04)
Prograxnined flxed fregency: 20:~iz
(Function code 01, 02, 03 or 04: data code 20)
Actual fixed ffreguency: 60Hz
of the three prograininable rotational
54
trequency setting
function code
open
closed
closed
usirig tunction codes 01, 02,
M3 33.0831 GB
[Hz] using
01
02
03
to the maximum freguencies.
page:
15
tactory
setting
10 Hz
20 Hz
30 Hz

Hide quick links: