MODBUS REGISTERS AND COILS

Flow Meter Registers

Descriptive Name
READINGS
Flow rate displayed on home screen . Unit is based on selection for
Flow Rate on Screen
home screen .
Fluid velocity displayed on home screen . Unit is based on selection for
Velocity on Screen
home screen .
Time of flight difference between upstream and downstream used to
Delta Time Filtered (ns)
calculated the flow rate . Units are nanoseconds .
Flow Rate (gal/min)
Flow rate in gallons/minute .
Velocity (ft/sec)
Fluid velocity in feet/second .
Flow Rate (l/min)
Flow rate in liters/minute .
Velocity (m/sec)
Fluid velocity in meters/second .
TOTALS
Total volume as forward flow minus reverse flow . A negative total results
Net Flow Totalizer
when reverse flow is greater than forward flow . Unit is based on selection for
(home screen units)
home screen .
Positive Flow Totalizer
Total volume of flow in forward direction . Reverse flow is not accounted for
(home screen units)
in the total . Unit is based on selection for home screen .
Negative Flow Totalizer
Total volume of flow in reverse direction . Forward flow is not accounted for
(home screen units)
in the total . Unit is based on selection for home screen .
Gross Flow Totalizer
Total volume of forward and reverse flow . Unit is based on selection for
(home screen units)
home screen .
Flow Totalizer
Overflow Counter
Number of times the net flow total overruns .
(Net)
Flow Totalizer
Overflow Counter
Number of times the positive flow total overruns .
(Positive)
Flow Totalizer
Overflow Counter
Number of times the negative flow total overruns .
(Negative)
Flow Totalizer
Overflow Counter
Number of times the gross flow total overruns .
(Gross)
Total volume as forward flow minus reverse flow . A negative total results
Net Flow Totalizer (gal)
when reverse flow is greater than forward flow .
Positive Flow Totalizer
Total volume of flow in forward direction . Reverse flow is not accounted for
(gal)
in the total .
Negative Flow Totalizer
Total volume of flow in reverse direction . Forward flow is not accounted for
(gal)
in the total .
Gross Flow Totalizer
Total volume of forward and reverse flow .
(gal)
Totalizer Overflow
Number of times the net flow total overruns .
Counter (Net)
Totalizer Overflow
Number of times the positive flow total overruns .
Counter (Positive)
Totalizer Overflow
Number of times the negative flow total overruns .
Counter (Negative)
Totalizer Overflow
Number of times the gross flow total overruns .
Counter (Gross)
Net Flow Totalizer
Total volume as forward flow minus reverse flow . A negative total results
(liters)
when reverse flow is greater than forward flow .
Positive Flow Totalizer
Total volume of flow in forward direction . Reverse flow is not accounted for
(liters)
in the total .
Negative Flow Totalizer
Total volume of flow in reverse direction . Forward flow is not accounted for
(liters)
in the total .
Gross Flow Totalizer
Total volume of forward and reverse flow .
(liters)
August 2019
Description
TTM-UM-03073-EN-01
Modbus Registers and Coils
Single
Integer and
Precision
Long Integer
32-bit
floating point
R
40001-40002
40601-40602
R
40003-40004
40603-40604
R
40005-40006
40605-40606
R
40201-40202
40801-40802
R
40203-40204
40803-40804
R
40401-40402
41001-41002
R
40403-40404
41003-41004
R
42001-42002
42301-42302
R
42003-42004
42303-42304
R
42005-42006
42305-42306
R
42007-42008
42307-42308
R
42009-42010
R
42011-42012
R
42013-42014
R
42015-42016
R
42101-42102
42401-42402
R
42103-42104
42403-42404
R
42105-42106
42405-42406
R
42107-42108
42407-42408
R
42109-42110
R
42111-42112
R
42113-42114
R
42115-42116
R
42201-42202
42501-42502
R
42203-42204
42503-42504
R
42205-42206
42505-42506
R
42207-42208
42507-42508
Double
Precision
64-bit
floating point
41201-41204
41205-41208
41209-41212
41401-41404
41405-41408
41601-41604
41605-41608
42601-42604
42605-42608
42609-42612
42613-42615
42701-42704
42705-42708
42709-42712
42713-42716
42801-42804
42805-42808
42809-42812
42813-42816
Page 5