1. Loosen the screw and remove the EVR cover.
EVR COVER
2. Connect the 2 pcs. of 30 pin flat cables (VFK1317) between P101/P102 on the Measuring Board (VFK1308P),
and 2 connectors on the EVR Connector Board (VFK1309A). Make sure that the contact surface of 2 pcs. of 30
pin Flat Cables are inner side and direction of the EVR Connector Board is as shown in Figures. Then connect
the Connection Adapter (VFK1763).
Connect VFK1763 with VFK1309A as
shown in picture.
If the connector is installed backwards,
it will not work.
3. Connect the Extension Cable (VFK1982) to Connection Adapter (VFK1763).
Connect VFK1982 with VFK1763 as
shown in picture.
The unit will not work if the connector
is attached backwards.
SCREW
VFK1763
Part side
Connect the
VFK1763
ELE-3
VFK1309A
30 pin Flat Cable
VFK1308P
VFK1982
VFK1763
VFK1309A