Durr Dental VS 300 S Installation And Operating Instructions Manual

Durr Dental VS 300 S Installation And Operating Instructions Manual

Combination suction unit

Advertisement

Combination Suction Unit
VS 300 S
VS 600
EN
VS 900 S / VS 1200 S
Installation and Operating Instructions
9000-606-79/30


Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VS 300 S and is the answer not in the manual?

Questions and answers

Summary of Contents for Durr Dental VS 300 S

  • Page 1 Combination Suction Unit VS 300 S VS 600 VS 900 S / VS 1200 S Installation and Operating Instructions 9000-606-79/30 ...
  • Page 3: Table Of Contents

    Content Mounting Important Information 8. Set-up  15 1. General  4 81 RoomforSet-up  15 11 NoteonConformity  4 82 Set-upalternatives 15 12 GeneralNotes  4 83 Bacterialfilter/noisereduction 13 Notesonmedicalproducts   4 (muffler)  15 14 NotesonEMCandmedicalproducts4 84 Installationofsurgetankincombi- 15 CorrectUsage  4 nationwithamalgamseparator 15 16 IncorrectUsage 5...
  • Page 4: Important Information

    •ThetranslationoftheseInstallationand Important OperatingInstructionshasbeencarriedoutin goodfaithNoliabilitycanbeacceptedfor Information mistakesinthetranslationTheenclosed GermanversionoftheseInstallationand 1. General OperatingInstructionsisthereferencever- sionIfthereisanydoubtaboutthetranslation 1.1 Note on Conformity pleaseconsultyourdealer Thisproducthasbeentestedforconformityac- •Anyreprintingofthetechnicaldocumentation, cordingtotheappropriatedirectivesaslaid inwholeorinpart,issubjecttopriorapproval downbytheEuropeanUnionandhasbeen ofDürrDentalbeinggiveninwriting foundtoconformtoalltherequired •Retainthepackagingforpossiblereturnofthe specifications producttothemanufacturersEnsurethatthe packagingisstoredawayfromchildrenOnly 1.2 General Notes theoriginalpackagingprovidesadequatepro- tectionduringtransportoftheunit •TheseInstallationandOperatingInstructions Shouldreturnoftheproducttothemanufac- formanintegralpartoftheunitTheymustbe turersbenecessaryduringtheguaranteeperi- keptclosetotheunitatalltimesPreciseob- od,DürrDentalacceptsnoresponsibilityfor servanceoftheseinstructionsisaprecondi- damageoccurringduringtransportwherethe tionforuseoftheunitfortheintendedpur- originalpackagingwasnotused! poseandforitscorrectoperation Newpersonnelmustbemadeawareofthe contents,andtheyshouldbepassedontofu- 1.3 Notes on medical products tureoperatingstaff •Thisproductisatechnicalmedicalappliance •Safetyfortheoperatoraswellastrouble-free...
  • Page 5: 16 IncorrectUsage

    Correctusageinfersthestrictobservanceofthe tientInspiteofthis,wefeelitisourdutyto InstallationandOperatingInstructionsandall mentionthefollowingsafetymeasuresinorder notesconcerningset-up,operationand topreventanypossibledanger maintenance •Whenusingthisappliancealllocalandrele- Installation within other medical supply vantregulationsmustbeobserved! equipment: Convertingormodifyingtheapplianceinany Duringdevelopmentandconstructionofthe wayisstrictlyprohibitedInsuchcases,any suctionunitcarehasbeentakentoincorporate andallguaranteesimmediatelybecome allrequirementsofmedicalproductsasfaras invalidTheoperationofmodifiedappliances waspossibleAsaresultthisapplianceissuita- canbepunishablebylawIntheinterestsof bleforinstallationwithinmedicalsupply trouble-freeoperationtheoperatorisrespon- equipment sibleforobservingtheseregulations Wherethisapplianceisinstalledwithinother •Installationmustbecarriedoutbyatechnical medicalsupplyequipmentthentheinstallation expert andassemblymustmeetallrequirementsofdi- •Beforeeveryusetheoperatormustcheckthe rective93/42EWGaswellasanyandallrele- functionalsafetyandtheconditionofthe vantstandards appliance •Theoperatormustbeknowledgeableinthe 1.6 Incorrect Usage operationoftheappliance Donotusethisappliancetoaspirateinflamma- •Theproductisnotdesignedtobeusedin bleorexplosivegasmixturesThisunitisnot medicaltreatmentareaswherethereexists suitableforuseasavacuumcleaner thedangerofexplosionAreaswhereexplo-...
  • Page 6: Warnings And Symbols

    3. Warnings and Symbols Intheoperatinginstructionsthefollowingwarn- ingsandsymbolshavebeenused: CAUTION Instructions including regulations and warnings regarding safety of persons and damage avoidance. Warning - dangerous electrical voltage. Automatic start up Hot surface Informationand/orinstructionsorprohi- bitionsregardingpersonalsafetyorex- tensivematerialdamage For their own protection, operating staff should always wear protective gloves when working with the suc- tion unit. Takeenvironmentalandambientcondi- tionsintoaccount Groundconnection 3.1 Model identification plate ThemodelidentificationplateoftheVS600/ VS900S/VS1200Scanbefoundonthetur- binehousingandontheVS300Sitislocated onthenoisereducerhousing(mufflerunit) Orderno/modelno Serial-No ObservetheOperatingInstructions Dateofmanufacturer 2010/11...
  • Page 7: Delivery Contents

    4. Delivery Contents 4.2 VS 600 S suction unit 4.2.1 Delivery contents Thepartslistedasspecialaccessories Model 7128-01/002 arenotpartofthestandardscopeof modeltype230V,1~,50Hz deliverybutcanbeorderedseparately withcontrolunit230V,1~ Model 7128-02/002 4.1 VS 300 S suction unit modeltype400V,3~,50-60Hz 4.1.1 Delivery contents withcontrolunit400V,3~ Model 7122-01/002 modeltype230V,1~,50Hz Model 7128-02/003 withcontroller modeltype230V,3~,50-60Hz withcontrolunit230V,3~ Model 7122-02/002 modeltype230V,1~,60Hz Model 7128-05/003 withcontroller modeltype200V,3~,50-60Hz withcontrolunit230V,3~ Model 7122-05/003 modeltype100V,1~,50-60Hz withcontroller 4.2.2 Accessories Controlunit formodel7128-01/002  0700-500-50 4.1.2 Accessories formodel7128-02/002  0732-100-56 Pipeconnectionset 7122-001-00 formodel7128-02/003  0732-100-57 formodel7128-05/003  0732-100-57...
  • Page 8: 43 Vs900SSuctionUnit

    4.3 VS 900 S suction unit 4.4 VS 1200 S suction unit 4.3.1 Delivery contents 4.4.1 Delivery contents Model 7134-01/002 Model 7138-02/002 modeltype230V,1~,50Hz modeltype400V,3~,50Hz withcontrolunit230V,1~ withcontrolunit400V,3~ Model 7134-02/002 Model 7138-02/003 modeltype400V,3~,50Hz modeltype230V,3~,50Hz withcontrolunit400V,3~ withcontrolunit230V,3~ Model 7134-02/003 Model 7138-03/002 modeltype230V,3~,50Hz modeltype400V,3~,60Hz withcontrolunit230V,3~ withcontrolunit400V,3~ Model 7138-03/003 4.3.2 Accessories modeltype230V,3~,60Hz withcontrolunit230V,3~ Controlunit formodel7134-01/002  0732-100-55 formodel7134-02/002  0732-100-56 4.4.2 Accessories formodel7134-02/003  0732-100-57 Controlunit Pipeconnectionset 7133-001-00 formodel7138-02/002  0732-100-61...
  • Page 9: Technical Data

    5. Technical Data 5.1 VS 300 S suction unit Model 7122 Voltage 230,1~ 230,1~ 100,1~ Frequency 50-60 Rated current 8,0-10 Starting current 21-20,5 Motor protection switch Motorwindingoverheatprotector160°C(±5°C) Power output 650-850 2750 3100 2810-3200 Duty cycle Fuse type IP24 Protection class Medical device ClassIIa Max. volume of fluid l/min Air flow rate seecharacteristics Weight withouthousing ca125 withhousing ca21 Noise levels ** withouthousing dB(A),±15 63-64 64-65 63-65 withhousing dB(A),±15...
  • Page 10: 52 Vs600SSuctionUnit

    5.2 VS 600 S suction unit Model 7128 Voltage 230,1~ 400,3~ 230,3~ 200,3~ Frequency 50-60 50-60 50-60 Rated current 1,8-2,3 3,1-4,1 3,2-4,0 Starting current Motor protection switch * 2,5-4,0 3,5-4,5 Power output 1100 1000 1420 1420 2850 2850/3300 Duty cycle Fuse type IP44 Protection class Medical device ClassIIa Max. volume of fluid l/min Air flow rate seecharacteristics Weight ca25 Noise levels ** withouthousing dB(A),±15 63-68 63-68...
  • Page 11: 53 Vs900SSuctionUnit

    5.3 VS 900 S suction unit Model 7134 Voltage 230,1~ 230/400,3~ Frequency Rated current 6,5/3,8 Starting current 42/25 Motor protection switch * 6,3/4 Power output 1680 1970 2780 2870 Duty cycle Fuse type IP44 Protection class Medical device ClassIIa Max. volume of fluid l/min Air flow rate seecharacteristics Weight ca32 Noise levels ** withouthousing dB(A),±15 withhousing dB(A),±15 Vacuum connection ø50mm(external) Exhaust air connection ø50mm(external) Waste water connection DürrConnectø20mm Auxiliary air valve settings mbar/hPa ca170...
  • Page 12: 54 Vs1200SSuctionUnit

    5.4 VS 1200 S suction unit Model 7138 Voltage 230/400,3~ 230/400,3~ Frequency Rated current 6,5/3,8 6,8/3,9 Starting current 43/25 Motor protection switch * 6,3/4 Power output 2000 2400 2860 3180 Duty cycle Fuse type IP44 Protection class Medical device ClassIIa Max. rate of flow of fluids l/min Air flow rate seecharacteristics Weight ca32 Noise levels ** withouthousing dB(A),±15 withhousing dB(A),±15 61,5 Vacuum connection ø50mm(external) Exhaust air connection ø50mm(external) Waste water connection DürrConnectø20mm Auxiliary air valve settings...
  • Page 13: 55 AmbientConditions

    6. Functional Description 5.5 Ambient conditions Takeenvironmentalandambientcondi- Example showing suction unit VS 900 tionsintoaccountDonotoperatethe Insidethesuctionunittheaspiratedfluidsand unitindamporwetconditions solidparticlesarepassedthroughatwo-step separationsystemandseparatedfromthesuc- Storage and transport tionairThisseparationsystemconsistsofa Temperature: –10°Cto+60°C cyclone s eparatorandaseparationturbine Relhumidity:   max95% Thesuctionoperationfunctionscontinuously Themixturedrawninconsistingoffluids,solid Operation particlesandairLuftpassesthroughtheinlet Temperature:+10°Cto+40°C connection(D)andintothesuctionunitThe Relhumidity:   max70% coarsefilter(B)servestoholdthesolidparticles backTherestofthemixturepassestothe cyclone s eparator(I)andissetintoaspiralmo- tionInthis first step thecentrifugalforces generatedcausethefluidandsmallerparticles remainingtobethrownagainsttheoutsidewall oftheseparationchamberofthecyclone- separatorThisinitiallycreatesacoarsesepara- tionofthefluidwaste Inthesecondstagetheseparationturbine(J) effectsafineseparationoftheremainingfluid...
  • Page 14: Functional Layout

    7. Functional layout A Auxiliaryairvalve G Exhaustairmufflerr B Coarsefilter H Wastewaterpump C Exhaustairconnection Cycloneseparator D Intakenozzle J Separationturbine E Wastewaterconnection K Turbinewheel F Membranevalve L Motor 2010/11...
  • Page 15: Set-Up

    Informationconcerninginstallationcan befoundintheinstallationinstructions Mounting providedwiththefloorunitorthewall mountingbracket 8. Set-up 8.3 Bacterial filter / noise reduction (muffler) Moreinformationcanbefoundinthe planninginformationforsuctionunits Bacterialfilter:forreasonsofhygienewestrong- lyrecommendthatabacterialfilterisprovided forintheexhaustairconnectionWherethe suctionunitisinstalledinthesurgeryroomsand 8.1 Room for Set-up theexhaustaircannotbefedtotheoutsideof •Installationinspecialpurposerooms,egin thebuildingthenabacterialfiltermustbefitted boilerroom,mustbecheckedfirstagainst Dependingonthemodeltypeandconditionof prevailingbuildingregulations thebacterialfilterthismustbereplacedevery •Installationinwetroomsisnotpermitted 1-2yearsatthelatest Noisereductionmuffler:wherethenoiseofthe •Wheninstallationisinacabinetoramachine exhaustairextractionattheoutletistooloud roomthensufficientintakeandexhaustair thenamufflercanbeinstalledintotheexhaust openingsmustbeprovidedfor;thesemust airline haveatleast120cm²clearcross-section Whereventilationisnotsufficient,thenaventi- 8.4 Installation of surge tank in lationfanmustbeprovidedwithaperform- anceofatleast2m³/min;appropriateslotsto combination with amalgam allowtheintakeofcoolairmustalsobepro- separator videdfor •SuctionunitsVS600,VS900SandVS1200 Whencabinetinstallationispreferredthena Srequiretheinstallationofasurgetankwhen...
  • Page 16: 86 Tubing

    8.6 Tubing The following materials may NOT be used: Acrylonitric butadiene styrene or Styrol-copolymer-blends (e. g. SAN+PVC). Only the following plumbing materials may be used: airtightHT-wastewatertubesofpolypropylene (PP),chlorinatedpolyvinylchloride(PVC-C),un- plasticizedpolyvinylchloride(PVC-U)andpoly- ethylene(PEh) 8.7 Hose materials The following materials may NOT be used: hose materials which are not re- sistant to dental disinfectants and chemicals, rubber hoses or full PVC-hoses which are not sufficient- ly flexible. Forwastewatersystemsandsuctionconnec- tionsonlyflexiblespiralPVChoseswithintegrat- edspiralorhosesofacomparablequalitymay beused Asallplastichosesaresubjecttodete- riorationwithage,thesemustbe checkedandinspectedfrequentlyand replacedwhennecessaryWhenasuc- tionunitisreplaced,werecommend thatallhoseconnectionsalsobere- placedatthesametime 8.8 Hose and pipe laying • Waste water connectionsmustbecarried outinstrictaccordancewithlocalandnational regulations Theconnectionbetweenthepipeline andconnectiontothesuctionunit shouldbekeptstraight,withoutbends, andasshortaspossibleusingtheflexi- blehosesprovidedThiswillreducethe amountofvibrationintheplumbing system 2010/11...
  • Page 17: Possible Connections

    9. Possible Connections Thealternativesetuparrangements shownherearedesignedonlytoindi- catetherangeofpossibilitieswhichwill varyaccordingtotheparticularsetup locationandconditions 9.1 Connection VS 300 S  1 Connector30/36 1a O-Ring  2 Hoseclampø30mm  3 Exhaustairhose(aluminium)ø30mm internal  4 ElbowpieceDN30  5 O-Ring30x2  6 Safetyclamp  7 ConnectorØ36mmexternal  8 O-Ring20x20  9 Safetyclamp 10 HosejointpieceØ25mm 11 Hoseclampø28mm 12 Suctionhoseø30mminternal 13 Hosesleeve 14 Wastewaterhoseø20mminternal...
  • Page 18: 92 ConnectionVs600

    9.2 Connection VS 600  5 O-Ring30x2  7 ConnectorØ36mmexternal  8 O-Ring20x20  9 Safetyclamp 10 HosejointpieceØ20mm 11 Hoseclampø28mm 13 Hosesleeve 14 Wastewaterhoseø20mminternal 21 Hoseclampø55mm 22 Exhaustairhoseø50mminternal 23 HoseconnectionsDN40/50 24 Hoseclampø46mm 25 Suctionhoseø40mm 2010/11...
  • Page 19 9.3 Connection VS 900 S / VS 1200 S  5 O-Ring30x2  7 ConnectorØ36mmexternal  8 O-Ring20x20  9 Safetyclamp 10 HosejointpieceØ20mm 11 Hoseclampø28mm 13 Hosesleeve 14 Wastewaterhoseø20mminternal 20 ElbowpieceDN50 21 Hoseclampø55mm 22 Exhaustairhoseø50mminternal 30 Straightinletconnection 31 Curvedinletconnection 32 Sealingsleeve 33 Lockingnut 34 Suctionhoseø55mminternal 2010/11...
  • Page 20: Electrical Connection

    10. Electrical Connection Fixed layout:(N)YM(St)-J4x15mm²shiel- dedplastic-sheathedcable Theelectricalconnectionsmustbecar- Flexible layout:datacableLiYCY4x10mm² riedoutobservinganyandalltechnical withshieldedcableasusedforITpurposesor regulationsconcerningthesetupoflow light-PVC-controllinewithshieldedcasing voltagesystemsinareasusedformedi- calpurposes 24 V Control line for VS 300 S •Beforestart-upandfirstusethesupplyvolt- Flexible layout:PVCdatatransmissioncable agemustbecomparedwiththevoltagein- LiYY3x05mm² structionstobefoundonthemodelidentifica- ordernumber9000-118-83 tionplate •Whencarryingoutelectricalconnectionsto 10.2 Control unit (VS 600, VS 900 S, themainpowersupplyanall-polarinsulating VS 1200 S) device(all-polarcircuitbreakerorall-polar Thesuctionunitcanbeconnectedtoacontrol powersafetyswitch(fused))withaminimum3 unitwhichiseitherpartofthedeliverycontents mmcontactopeningwidthmustbebuiltinto or,ifnot,canbeorderedasaspecialaccesso- thesystem ryConnectionplansandcircuitdiagramscan •Suctionunitscanonlybeconnectedtothe befoundintheControlUnitInstallationand mainspowersupplyusingafixedcable OperatingInstructions connection Thecontrolboxisfactorysetforcon- •Thesuctionunitisoperatedusingthecontrol- nectiontothesuctionunit;thisshould lerlocatedintheexternalcontrolunit bekeptinmindwhenreplacingthesuc- Circuitprotection:LS-switch16A, tionunitwithaunitofadifferentsize...
  • Page 21: 103 MotorTerminalBoxConnections

    10.3 Motor terminal box connections Connectthepowersupplylinefromthecontrol unittotheappropriateterminalinthemotorter- minalbox 10.3.1 VS 300 S 1/N/PEAC230V,withcontrollerintegratedin thenoisereductionhousing,seefig11 X1 Powersupplyconnection X2 Motorconnection X3 Hosemanifold24VAC/max80mA connection X4 Controlsignaloutput 24VAC/max20mA 10.3.2 VS 600, 230V1~ VS 900 S, 230V1~ 10.3.3 VS 600,230V/400V3~ VS 900 S,230V/400V3~ VS 1200 S,230V/400V3~ 2010/11...
  • Page 22: Start-Up

    HandlingterminalstripinterminalboxofVS 600,VS900SandVS1200S 11. Start-up The suction unit must not be opera- ted without the coarse filter, other- wise larger particles such as bits of broken tooth or fillings could cause damage to the unit. •Checkthatthecoarsefilters(eginspittoon) havebeenplacedinposition •Switchontheunitpowerswitchorthemain surgeryswitch •Carryoutafunctioncontrolofthesuctionunit andthecontrolunit Checkthemotorrotationdirection(3/N/PE AC) Setthemotorprotectionswitchinthecontrol unit •Checkallconnectionsforsignsofleakages •Carryoutanelectricalsafetycheckofthe controlunitandthesuctionunitaccordingto nationalandlocalregulations(eganyandall regulationsconcerningsetup,operationand applicationofmedicalproducts)andrecord theresultsasappropriate,eginthetechnical logbook Inmanycountriestechnicalmedical productsandelectricaldevicesaresub- jecttoregularchecksatsetintervals Theoperatorshouldbeinformedas necessary 2010/11...
  • Page 23: 12. Cleaning And Disinfection Of The Suction Unit  23

    13. Maintenance Wear water-proof protective gloves! 12. Cleaning and disinfec- Every 4 weeks (for VS 600, VS 900 S, tion of the suction unit VS 1200 S every 3 months)thefilterlocatedat thesuctionconnectionofthesuctionunit Do not use any foaming agent, e.g. shouldbecheckedandcleanedifnecessaryTo household cleaning agent, instru- dothis,slidethesuctionhosefromthesuction ment disinfection agent or abrasive unitconnectionIfrequired,extractthefilter cleaners. fromthesuctionconnectionpieceandclean Do not use agents containing chlo- A Service Technician is required to check rine or any sort of solvent such as the condition(egsignsofleakagesoraging)of acetone. These agents can affect thewasteconnectionvalvesatleastonceayear the materials. This will lead to loss andtoreplaceifnecessary of any claims under the guarantee. For reasons of hygiene and perfect func- Everytwoyears(VS600,VS900S,VS1200S) tion, after every patient treatment theauxiliaryairvalvemustbecheckedand oneglassofcoldwatershouldbeaspirated cleanedand/orreplacedasnecessary throughboththelargerandthesmallerofthe suctionhoses-evenifonlythesalivaextractor Theexhaustairbacterialfilter(whenpresent) wasusedforaspiration shouldbereplacedevery12-24months Aspirationusingthelargersuctionhose Theintegratedseparationunitwithinthe allowsalargeramountoffreshair(~300 suctionunitdoesnotholdbacteria l/min)tobedrawnupandthisincreases back,whichiswhyitisstronglyrecom- considerablythecleaningefficiency mendedtoinstallabacterialfilterinthe...
  • Page 24: Trouble-Shooting

    Trouble-shooting 14. Tips for Operators and Technicians Any repairs above and beyond routine maintenance must be carried out by suitably qualified personnel or one of our service technicians. Before starting any trouble-shooting activities ensure that the appliance has been re- moved from the power supply. Problem Probable cause Solution 1. Suction unit does •Nosupplyvoltage •Checkthemainsfusing,fusein not start up. controlunitoronthePCBandre- placeifnecessary Checksupplyvoltage •Underorovervoltage •Measurethesupplyvoltage,ifnec- essarycallanelectrician •Motorprotectionswitchsettoolow •MeasurecurrentSetthemotor (forvaluesseeTechnicalData) protectionswitchtomeasuredval- ueplussafetymargin •Motorprotectionswitchdefectly •Checkmotorprotectionswitch;if defectly,replace •Capacitordefectly •Measurethecapacitanceandre- placeifnecessary •Turbineisblockedduetosolidpar- •Disassemblethesuctionunitand ticlesordirt(egbyusingunsuita- cleantheturbine blecleaninganddisinfectant agents);motorprotectionswitch activated 2. Suction unit produ- •Solidparticlesinturbine •Disassemblethesuctionunitand ces unusual noises.
  • Page 25: Disposal

    Problem Probable cause Solution 4. Suction unit perfor- •Mechanicalsluggishnessofturbine •Disassemblethesuctionunitand mance too low. causedbydirt cleantheturbine •Coarsefilterblocked •Cleancoarsefilteratintakenozzle •Suctionconnectionnotwaterproof •Checkthesuctionlinesandcon- nectionsforleaksandcorrectas necessary Disposal 15. Appliance disposal Theunitcouldpossiblybecontaminat- edInformthewastemanagementcom- panysothattheycantakeallnecessary safetysteps Non-contaminatedplasticpartsofthe suctionunitcanbedisposedoffor recycling Thecontrolboard,electronics(PCB)andcom- ponentsareelectronicwasteandmustbedis- posedofasappropriateOthermetalparts(e gturbinehousing)canbedisposedofasmetal waste Whenreturningtheappliance,egtoyour dealer´sdepotortoDürrDental,besureto closeallconnections 2010/11...
  • Page 28 DÜRR DENTAL AG Höpfigheimer Strasse 17 74321 Bietigheim-Bissingen Germany Fon: +49 7142 705-0 www.duerr.de info@duerr.de...

This manual is also suitable for:

Vs 600Vs 900 sVs 1200 s

Table of Contents

Save PDF