16 • vacon
6.
COMMISSIONING
READ FIRST CHAPTER 8 'COMMISSIONING' IN VACON NX USER'S MANUAL (Document nr. ud00701,
please visit http://www.vacon.com/support/documents.html).
Note! You must select Fieldbus as the active control place, if you wish to control the frequency
converter through fieldbus. See Vacon NX User's Manual, Chapter 7.3.3.1
The Vacon CanOpen board is commissioned with the control keypad by giving values to appropriate
parameters in menu M7 (for locating the expander board menu see Vacon NX User's Manual, Chapter
7).
Expander board menu (M7)
Expander board menu
The
connected to the control board and 2) to reach and edit the parameters associated with the expander
board.
Enter the following menu level (G#) with the
slots A to E with the
line of the display you also see the number of parameter groups associated with the board.
If you still press the
two groups: Editable parameters and Monitored values. A further press on the
takes you to either of these groups.
CanOpen parameters
To commission the CanOpen board, enter the level P7.5.1.# from the
desired values to all CanOpen parameters (see xx and xx).
READY
Expander boards
G1
READY
Node ID
63
Figure 6-1. Changing the CANopen option board parameters
Tel.+358-(0)201-21
6
makes it possible for the user 1) to see what expander boards are
Browser buttons
to see what expander boards are connected. On the lowermost
Menu button right
once you will reach the parameter group level where there are
E:NXOPTC6
G5
G1
Node ID
Menu button right
. At this level, you can browse through
READY
Parameters
G2
READY
enter
63
Tel. +358 (0)201 2121 • Fax +358 (0)201 212 205
commissioning
Menu button right
Parameters
group (G7.5.1). Give
READY
P1
P3
CHANGE VALUE
CONFIRM CHANGE