Error List - Cablescan 128/PC Instruction Manual

Continuity tester and fixture
Table of Contents

Advertisement

Page 16

Error List

This mode requires hookup of the optional printer. When ERROR LIST is selected, it performs
a single test and prints a list of errors encountered, or it prints Passed when there are no errors.
Sample error lists using adapter connector numbers and user labels are shown in Figure 10. To
select and use ERROR LIST, proceed as follows:
1. Press RESET.
2.
Select and install a pair of adapter cards for the cable assembly to be tested.
3.
Mate each connector on the cable assembly to the appropriate adapter card.
4.
Verify printer is connected. (Refer to Printer Setup in System Setup section.)
5.
Load program to be used. (Refer to "Load Program" later in this section).
6.
Press ERROR LIST. The Model 128/PC performs a single test and prints a list of all
errors, or prints Passed if there are no errors.
7.
When test and printout are finished, disconnect harness.
Adapters A: 05 B: 06 Signature: 1066
-------------------------------------------------
Error List
Condition
-------------------------------------------------
OPEN
SHORT
OPEN
SHORT
OPEN
Failed
Adapters A: 05 B: 06 Signature: 1066
-----------------------------------------------
Error List
Condition
-----------------------------------------------
OPEN
SHORT
OPEN
SHORT
OPEN
Failed
From Point
To Point
A 3
A 3
A 1
A 8
A 8
(Error list without user labels)
From Point
To Point
J1-3
P1-3
J1-3
P1-1
J1-1
P1-1
J1-8
P1-3
J1-8
E2
(Error list with user labels)
Figure 10. Sample Error List Printouts
Model 128/PC Instruction Manual
B 12
B 10
B 10
B 12
B 16