How Do I Program The System; Single Digit Data Entry Method (Hexadecimal And Decimal); Multiple Feature Select Programming Method - Paradox Spectra 1725 Programming Manual

Table of Contents

Advertisement

HOW DO I PROGRAM THE SYSTEM?

TM
The Spectra
series control panels can be programmed using the WinLoad Software or by using any keypad connected to
the Spectra control panel. For information on the WinLoad Software, please refer to the Spectra Installation & Reference
Manual. To program the Spectra control panel using a keypad, you must enter the Programming Mode as shown below.
Once a control panel has been programmed, you can use the Paradox Memory Key to copy the contents from the
programmed control panel to one or more control panels (see page 5).
Default Installer Code: 000000 (see section [281] on page 20)
Default System Master Code: 123456 (see section [301] on page 21)

SINGLE DIGIT DATA ENTRY METHOD (Hexadecimal and Decimal)

Single Digit Data Entry is used in all sections except those specified in Multiple Feature Select Programming Method. After
entering the programming mode as described in the shaded box above, some sections will require that you enter Decimal
values from 000 to 255. Other sections will require that you enter Hexadecimal values from 0 to F. The required data will be
clearly indicated in this manual. When entering the final digit in a section, the control panel will automatically save and
advance to the next section. With the exception of sections 001 to 016, where after entering the first two digits, the control
panel will switch to Multiple Feature Select Programming.
Value or Action
Values 1 to 9
A
(hexa only)
B
(hexa only)
C
(hexa only)
D
(hexa only)
E
(hexa only)
F
(hexa only)
Erase Current Digit
Exit Without Saving
Save Data
(hexa only)

MULTIPLE FEATURE SELECT PROGRAMMING METHOD

Sections: [001] to [016], [127] to [138], [302] to [348], [610], [650] to [651]
After entering the programming mode as described in the shaded box above, each option from [1] to [8] will represent a
specific feature or option. Press the key corresponding to the desired option and the corresponding light will illuminate or the
option number will appear in the LCD display. This means the option is on. Press the key again to extinguish the
corresponding light or remove the digit from the LCD display, thereby, turning off the option. Please note that pressing the
[
] key will set all 8 options to "off". Press the keys as many times as you need until all 8 options in the current section
FORCE
are set. When the options are set, press the [
4
Programming Guide
To enter Programming Mode:
STEP 1: Press [
ENTER
STEP 2: Enter your [
INSTALLER CODE
STEP 3: Enter 3 digits of [
STEP 4: Enter required [
Table 1: Decimal and Hexadecimal Programming Table
What Do I
Press?
10-Zone LED
[1] to [9]
[1] to [9]
[0]
[
]
STAY
[
]
BYP
[
]
MEM
[
] / [
]
TBL
TRBL
[
] / [
1]
PG
FNC
[
]
FORCE
[
]
[
CLEAR
ENTER
[
]
ENTER
] key to save and advance to the next section.
ENTER
]
]
] you wish to program
SECTION
]
DATA
What Do I See?
16-Zone LED
[1] to [9]
[0
]
[10]
(10)
[
]
[11]
STAY
[
]
[12]
BYP
[
]
[13]
MEM
[
]
[14]
TBL
[
]
[15]
PG
Displays next digit or next section
] flashes [
] & [
ARM 1
STAY 1
Advances to the next section
LCD
[1] to [9]
A
B
C
D
E
F
] flash "SECTION [
]"

Hide quick links:

Advertisement

Table of Contents
loading