Paradox SPECTRA 1727 Installation Manual

Paradox SPECTRA 1727 Installation Manual

Hide thumbs Also See for SPECTRA 1727:

Advertisement

S
1727 V1.10
PECTRA
1727
C
I
M
OMPLETE
NSTALLATION
ANUAL
Reference, Installation and Programming

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPECTRA 1727 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Paradox SPECTRA 1727

  • Page 1 1727 V1.10 PECTRA 1727 OMPLETE NSTALLATION ANUAL Reference, Installation and Programming...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Introduction ............................2 Features........................................2 Specifications......................................2 Spectra 1727 Control Panel ......................................2 Spectra 1686H and 1686V 10-Zone LED Keypads ................................ 2 Programming Methods..................................... 2 Single Digit Entry Method ....................................... 2 Multiple Feature Select Programming Method ................................2 Installation..............................
  • Page 4: Introduction

    INTRODUCTION FEATURES • 6 Programmable Zones: 4 Zones, 1 Keypad Zone, 1 Fire/24Hr. Burglary Zone • 1 Installer Code and 8 User Codes (1 System Master and 7 User Codes) • 2 Programmable Outputs • Regular Arming, Stay Arming, Force Arming, One-touch Arming, and Bypass Programming •...
  • Page 5: Ac Power

    Section [13] The Spectra 1727 control panel includes two programmable outputs (PGMs) that provide a maximum of 50mA each. When a specific event occurs in the system, a PGM can reset smoke detectors, activate strobe lights, open/close garage doors and much more. Connect the PGMs according to Figure 8-3: PGM Connections on page 14.
  • Page 6: Zone Inputs

    The keypad has one zone input terminal that allows you to connect one motion detector or one door contact directly to the keypad. The keypad zone is recognized as zone 5. Only one keypad zone can be used per Spectra 1727 control panel. The keypad communicates the status of the keypad zone to the control panel once the device is connected as shown in Figure 8-1: PCB Layout on page 13 and the zone’s parameters are...
  • Page 7: Zone Programming

    Select the zones from 1 to 5 to be Follow Zones. Zone 6 is a 24-Hour Zone or a Fire Zone (see section 3.2) and cannot be programmed as a Follow Zone. Also, refer to Zone Speed (see section 3.3). Spectra 1727 5...
  • Page 8: Fire Zone Programming

    Section [19] option [6] In case of emergency, the Spectra 1727 system provides one panic alarm. This panic alarm, if enabled, will immediately generate an alarm after pressing and holding the [1] and [3] keys for two seconds. In the Alarm Memory (see section 6.8) the [8] key will illuminate to indicate that someone activated the Panic Alarm.
  • Page 9: One-Touch Arming

    The System Master Code can be 4 or 6 digits in length (see section 5.1), where each digit can be any digit from 0 to 9. To change the System Master Code press: ENTER CURRENT SYSTEM MASTER CODE + [02] + new 4- or 6-digit System Master Code Spectra 1727 7...
  • Page 10: User Access Codes

    USER ACCESS CODES Spectra 1727 supports 9 access codes. Eight access codes are available for the users. Programming User Access Codes is explained User Access Codes in more detail in section on page 9. USER OPERATION DISARMING & DEACTIVATING AN ALARM To disarm an already armed system or to deactivate an alarm simply key in a valid access code.
  • Page 11: Bypass Recall

    How Do I Delete Access Codes? 1) Repeat steps 1 to 3 (see above) 2) Press the [ ] button once for each digit in the access code FORCE (4 or 6 times) until the keypad emits a Confirmation Beep. Spectra 1727 9...
  • Page 12: Panic Alarms

    All other beep functions are disabled. PROGRAMMING GUIDE To program the Spectra 1727 control panel, use a keypad to enter the Programming Mode as shown below. DEFAULT INSTALLER CODE: 0000/000000...
  • Page 13: System Timers

    Ready “PG” Key “PG” Key Fire Alarm Fire Alarm Alarm Alarm Strobe Strobe Entry Delay/Exit Delay/Alarm Entry Delay/Exit Delay/Alarm Exit Delay/Armed Entry Delay/Alarm Regular Arming Entry Delay/Alarm [13] ____/____PGM 1 / PGM 2 (default: 3 / 3) Spectra 1727 11...
  • Page 14 ZONE PROGRAMMING How Do I Program the Zones? STEP 1: Press the [ ] key ENTER STEP 2: Enter the [ ] (Default: 0000/000000) INSTALLER CODE STEP 3: Enter the 2-digit [ ] representing the Zone Option (all zones Entry Delay by default) SECTION STEP 4: Select zone(s) by pressing the corresponding key.
  • Page 15: Hardware Connections

    HARDWARE CONNECTIONS Figure 8-1: PCB Layout Spectra 1727 13...
  • Page 16 Figure 8-2: Zone Connections Figure 8-3: PGM Connections 14 Complete Installation Manual...
  • Page 17 Legal Notice © 2002-2003 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following US patents may apply: 5751803, 5721542, 5287111, 5119069, 5077549, Canadian and international patents may also apply. Spectra is a trademark or registered trademark of Paradox Security Systems Ltd.
  • Page 18 Notes 16 Complete Installation Manual...