INSTALLER CODE (Default: 282828)
Full access to programming, except user access codes (PINs). No access to arming/disarming. Use only numeric keys from [0] to [9].
ZONE RECOGNITION
STREAMLINED SECTION PROGRAMMING
This is an alternate method to Hexa Programming (see page 2). Addresses 000 to 043 and 300 to 527 are grouped into 67 sections where
each section contains four addresses (i.e. section 00 = addresses 000 to 003). Using this method allows you to program 8 digits (4
addresses) without having to exit and reenter addresses.
Note, the keypad will not display the current data in the Streamlined Section Programming method.
1)
2)
3)
4)
5)
6)
7)
KEYPAD TROUBLE DISPLAY
Press the [
]/[
] key to view the trouble. Any illuminated keys represent a specific trouble as indicate in Table 3 below. Press the
TBL
TRBL
[
] button to exit the trouble display.
CLEAR
[1]
[2]
[4]
[5]
[6]
S
P
YSTEM
ROGRAMMING
Table 1: Zone Recognition
Device connected to which input?
Control Panel
Input 1 =
Input 2 =
Input 3 =
Input 4 =
Keypad
Zone 1 =
Zone 2 =
Table 2: Streamlined Section Programming Method
Press [
] + [
ENTER
INSTALLER CODE
The [
] and [2
] keys will flash to indicate you are in programming mode
ENTER
ND
Enter 2-digit [
] (00 to 67)
SECTION
The [
] key will remain on while the [2
ENTER
Enter 8-digit [
] to program the section
DATA
The keypad will "beep" to indicate that the section has been programmed, data is
saved and the software has advanced to the next section
Return to step 4 or press [
- No Battery or Low Voltage
- Power Failure
- Bell Output Disconnected
- Exceeded Maximum Bell Current
- Exceeded Maximum Auxiliary Current
Esprit 728 Ultra - 1 - Programming Guide
G
UIDE
Software Version 4.0
No ATZ
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
] (default: 282828) + [7]
] key will be off
ND
] to exit programming mode
CLEAR
Table 3: Trouble Display
[7]
- Communicator Report Failure
[8]
- Timer Loss* (to clear, see
in Table 11 on page 11)
[9]
- Tamper or Zone Wiring Failure
[10]
- Telephone Line Monitoring Failure
[11]
- Fire Loop Trouble
(728ULT)
With ATZ
Zones 1 & 2
Zones 3 & 4
Zones 5 & 6
Zones 7 & 8
Zone 9
Zone 10
[
]
MEM
key

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Esprit 728 ultra and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Paradox Esprit 728 ultra

  • Page 1 Table 11 on page 11) - Bell Output Disconnected - Tamper or Zone Wiring Failure [10] - Exceeded Maximum Bell Current - Telephone Line Monitoring Failure [11] - Exceeded Maximum Auxiliary Current - Fire Loop Trouble Esprit 728 Ultra - 1 - Programming Guide...
  • Page 2: Hexa Programming

    Identifies the control panel to the PC. ___ / ___ Panel Identifier (3rd, 4th digit) ___ / ___ PC Password (1st, 2nd digit) Identifies the PC to the control panel. ___ / ___ PC Password (3rd, 4th digit) Esprit 728 Ultra - 2 - Programming Guide...
  • Page 3: Telephone And Account Numbers

    Account “A” and “B” (View at addresses 032 to 035) Streamline Section For 3 digit account numbers, enter “skip” __/__/__/__ __/__/__/__ ]) as first digit. 1 2 3 4 5 6 7 8 Esprit 728 Ultra - 3 - Programming Guide...
  • Page 4 601: [4] / [2 EMPERATURE TRBL ANUAL 159: [2] / [2 602: [4] / [1] EMPERATURE ERIODIC 161: [2] / [1] 625: [4] / [2] ESET 654: [4] / [3] YSTEM NACTIVITY Esprit 728 Ultra - 4 - Programming Guide...
  • Page 5: Reporting Codes

    User Code 45 ___ / ___ User Code 22 ___ / ___ User Code 46 ___ / ___ User Code 47 ___ / ___ User Code 48 / (Duress) Continues on next page. Esprit 728 Ultra - 5 - Programming Guide...
  • Page 6 ] / [2 Future Use ] / [2 Future Use ] / [2 Future Use ] / [2 Future Use 39 to 41 Future Use 412-423 45 to 47 Future Use 436-447 Esprit 728 Ultra - 6 - Programming Guide...
  • Page 7 Late to close ___ / ___ Login (Espload) ___ / ___ No movement ___ / ___ Program Change ___ / ___ Partial Arming Future Use ___ / ___ Recent Close Future Use Esprit 728 Ultra - 7 - Programming Guide...
  • Page 8: Decimal Programming

    If address 090 key [3] OFF = address 061 in days (see page 10) If address 090 key [3] ON = address 061 in hours (see page 10) Figure 2: Decimal Display For LED Keypads Esprit 728 Ultra - 8 - Programming Guide...
  • Page 9: Feature Select Programming

    072: Table 9: Code Priority for Codes with Bypass Access KEY SELECT: [1] [9] [10] [11] [12] [ ] [2 TRBL User #: 074: User #: 17 076: User #: 33 078: Esprit 728 Ultra - 9 - Programming Guide...
  • Page 10 Enabled Keypad zone 1 supervision [11] Enabled [12] Keypad zone 2 supervision Enabled Master code lock Enabled Pager format (wait delay) Personal dialing (during delay) Pager report alarms only All events TRBL Esprit 728 Ultra - 10 - Programming Guide...
  • Page 11: Key Access Programming

    “modem setup” section and panel phone number programmed. Cancel Communication Attempts Master Code/User Code 1 only cancel calls to Espload STAY The Installer Code can cancel all communications Until next reportable event. Esprit 728 Ultra - 11 - Programming Guide...
  • Page 12: Connection Diagrams

    Figure 7: N.C. Contacts, with EOL resistor, with Tamper and Wire Fault Recognition (UL/ULC) Address 088, [ ] = “OFF” (EOL resistor enabled) [10] = (See Tamper/Wire Fault definitions on [11] = page 10.) Address 090, [8] = “OFF” (ATZ disabled) Esprit 728 Ultra - 12 - Programming Guide...
  • Page 13: Other Connection Diagrams

    [11] = page 10.) Address 090, [7] = “ON” (ATZ wiring in parallel) Address 090,[8] = “ON” (ATZ enabled) [8] = “ON” (ATZ enabled) OTHER CONNECTION DIAGRAMS Figure 12: Connecting One Keypad Zone Esprit 728 Ultra - 13 - Programming Guide...
  • Page 14 Figure 15: PGM Output Relay Figure 16: Ground Start Circuit Figure 17: Fire Alarm Zone Connections Figure 18: Fire Reset Note: It recommended that the smoke detectors be connected using a daisy chain configuration. Esprit 728 Ultra - 14 - Programming Guide...
  • Page 15: Wiring Diagram

    Refer to Figure 12 and Figure 13 on pages 13 and 14 for information on keypad zone connections. output BELL will shutdown if Bell/Siren: the current UL/ULC exceeds 3A. Wheelock 46T-12 Esprit 728 Ultra - 15 - Programming Guide...
  • Page 16 03/2003 728ULT-EP00 PRINTED IN CANADA...