Alarms - Sullair LS-32 Operator's Manual And Parts List

Industrial rotary screw air compressor 350-400hp low pressure air-cooled standard and 24kt
Table of Contents

Advertisement

Section 5
SUPERVISOR CONTROLLER™
Table 5-1 Alarms
Sensor
System Check
I/O Module Check
Com Module Check
Motor Module Check
Module
D_1
D_2
D_3
D_4
E_1
E_2
AIR FILTER MAINT.
OIL ANALYSIS Check
OIL CHANGE Check
OIL FILTER MAINT.
SEPARATOR CHANGE
Check
dP_1
dP_2
dP_3
dP1Max
dP1Max
P_1
P_1
P_1
P_2
P_3
P_4
T_1
T_1
T_1
T_1
T_1
T_1
T_2
T_2
T_2
T_3
T_3
T_4
T_4
(*) In the 'Check' column above, alarms are checked :
Constantly - if machine running or stopped
When Running - if machine is running
If Enabled - if parameter is non-zero
At Start - will not allow start if alarm present
Over Min Psi - machine is loaded and above min load pressure
34
Type
Limit
On Fault
0
On Fault
0
On Fault
0
On Fault
0
On Fault
0
On Fault
0
On Warn
0
On Fault
0
On Fault
0
On Fault
0
Maint Warn
0
Maint Warn
0
Maint Warn
0
Maint Warn
0
Maint Warn
0
High Warn
10
High Warn
20
Low Fault
1
High Fault
0
High Warn
3
High Inhibit
5
Low Fault
5
High Fault
500
High Fault
500
High Fault
500
High Fault
500
Low Fault
-40
High Warn
225
High Fault
235
High Warn
245
High Fault
255
High Fault
500
Low Fault
-40
High Warn
225
High Fault
235
Low Warn
-40
High Warn
500
Low Fault
-40
High Fault
500
Start
Run
Delay
Delay Check (*)
0
0
Constantly
0
0
Constantly
0
0
Constantly
0
0
Constantly
1
1
Constantly
1
1
Constantly
5
5
When Running
5
5
When Running
0
0
Constantly
0
0
Constantly
0
0
If Enabled
0
0
If Enabled
0
0
If Enabled
0
0
If Enabled
0
0
If Enabled
5
55
Over Min Psi
5
2
When Running
5
55
When Running
5
0
When Running
5
0
When Running
0
0
At Start
5
0
When Running
0
0
Constantly
0
0
Constantly
0
0
Constantly
0
0
Constantly
0
0
Constantly
5
30
Constantly
5
30
Constantly
0
0
Constantly
0
0
Constantly
0
0
Constantly
0
0
Constantly
5
30
Constantly
5
30
Constantly
0
0
Constantly
0
0
Constantly
0
0
Constantly
0
0
Constantly
Comment
Factory Setup Check Sum Fail
Communication failure I/O Module
Communication failure Com Module
Communication failure Motor
Motor overload
Aux motor overload
Air filter maintenance
Low water pressure
E-Stop Push Button
Auxiliary E-Stop
Air Filter change due
Oil Analysis due
Oil change due
Oil filter change due
Separator change due
Separator maint P1-P2
Oil filter maint P4-P3
Low Oil psi P3-(P1/2.5)
dP1Max = P1Max - P1
dP1Max = P1Max - P1
High sump psi at start
Immediate Fault
Sensor failure fault
Sensor failure fault
Sensor failure fault
Sensor failure fault
Sensor failure fault
Delayed for temp spikes
Delayed for temp spikes
Immediate Warning
Immediate Fault
Sensor failure fault
Sensor failure fault
Delayed for temp spikes
Delayed for temp spikes
Sensor failure warning
Sensor failure warning
Sensor failure fault
Sensor failure fault