Sullair V-200TS Operator's Manual And Parts List page 35

Industrial air compressor 100-250hp/75-187kw air-cooled and water-cooled standard & 24kt
Hide thumbs Also See for V-200TS:
Table of Contents

Advertisement

Section 6
MAINTENANCE
6.1 SPIRAL VALVE PRESSURE REGULATOR
Figure 6-1 Pressure Regulator Adjustment
See Figure 6-1. This downstream pressure regula-
tor protects the spiral valve actuator diaphragm
from over pressurization and ensures that ade-
quate pressure is supplied for proper operation.
To set the regulator, slowly decrease demand until
the compressor runs at minimum speed. As a result
the spiral valve solenoid becomes de-energized,
feeding air pressure to open the spiral valve.
Unlock and turn the adjustment screw located on
the bottom of the regulator valve to set the desired
pressure. Once 38-40 psig is reached on the down-
stream gauge, lock the adjustment screw.
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents