f.
We recommend to remove old grease from spindles and lubricate these with new
grease. Also, excessive lubrication from linear guides can be removed to prevent it
from falling on electronics or printing table. Please check this after every 10.000
printing sessions, especially after the first 10.000 sessions.

6.2 Advanced maintenance

6.2.1 Advanced maintenance by technician

Please inspect the following components at every check-up (after every 10.000 to 25.000
printing sessions or at least 1-2 times per year). Maintenance described below must be done
by a professional with the required knowledge and experience. Please contact your
distributor first.
a. All cables, connections and sensors should be inspected at every check-up.
b. Screws, especially on printhead assembly, can be checked/fastened at every check-
up. Inspect the paly in components.
c.
Printhead must be inspected for mechanical damage at every check-up. When
original foil is used and the printhead is well maintained, it has a lifetime of 25km.
d. Inspect pressure movement smoothness and loose parts. Inspect the minimum and
maximum pressure as well as torque sensor test via testing and calibration menu.
Inspect the connector at the loadcell (pressure sensor) and printhead. These must
be examined at every check-up.
e. We advise you to replace the mechanism [SPUP0000134] with a new one or to send
this to us/your dealer for revision after every 50.000 printing sessions. Attention! To
be done by a professional with professional tools.
Figure 66: SPUP0000134 - Head plate for Z-axis subassembly – GEN 2