Huawei SUN2000-50KTL-M0 User Manual page 13

Hide thumbs Also See for SUN2000-50KTL-M0:
Table of Contents

Advertisement

SUN2000-(50KTL-M0, 70KTL-INM0)
User Manual (India Edition)
Communication
LED
Alarm/Maintenance
LED
Issue 03 (2019-07-30)
Off
Blinking green (on for 0.2s and
then off for 0.2s)
Off
Alarm
status
Local
maintenance
status
Local maintenance refers to operations performed after a USB flash drive, a WLAN module, a
Bluetooth module, or a USB data cable is inserted into the USB port of the solar inverter. For
example, local maintenance includes data import and export using a USB flash drive, and connecting
to the SUN2000 app over a WLAN module, a Bluetooth module, or a USB data cable.
If the alarming and the local maintenance happen concurrently, the alarm/maintenance indicator
shows the local maintenance state first. After the USB flash drive, WLAN module, Bluetooth
module, or USB data cable is removed, the indicator shows the alarm state.
Copyright © Huawei Technologies Co., Ltd.
The SUN2000 is not exporting
power to the power grid.
The SUN2000 receives
communications data normally.
The SUN2000 receives no
communications data for 10s.
Blinking red at
The SUN2000 is generating a
long intervals (on
warning alarm.
for 1s and then off
for 4s)
Blinking red at
The SUN2000 is generating a
short intervals (on
minor alarm.
for 0.5s and then
off for 0.5s)
Steady red
The SUN2000 is generating a
major alarm.
Blinking green at
Local maintenance is in
long intervals (on
progress.
for 1s and then off
for 1s)
Blinking green at
Local maintenance fails.
short intervals (on
for 0.125s and
then off for
0.125s)
Steady green
Local maintenance is
successful.