INSTALLATION AND COMMISSIONING

DANGER!
Danger of explosion!
The device is a sealed system. The unit must not be dismantled!
The following safety regulations must be observed:
The surface of the device may develop an electrostatic charge.
In areas with an explosion hazard, the surface of the units may only be
cleaned with a damp cloth!
Only permanently laid cables and wiring may be inserted.
The operator must provide suitable stress relief.
Wires with an outside diameter of 6 to 13 mm may be used. Observe
the maximum thermal loading of the cables or wires to be inserted.
The inserted break-off seal must be matched to the diameter of the
cable or wire.
The rated cross-section of the cable or wire strands must be at least
0.75 mm² and may not exceed 2.5 mm².
The screws for fixing the cover of the terminal box must be tightened
with a torque of 100 Ncm (±5%).
DANGER!
High voltage!
Acute risk of injury from hazardous structure-borne voltage!
Risk of damage to the device due to short circuit!
Work on the electrical system may only be carried out by qualified
electricians.
Before starting work, switch off the power supply and secure to
prevent it being switched on again!
Live terminals in the terminal box can cause electric shock, short circuit
or explosion. Switch off the power supply before opening the terminal
box.
The connecting cables to the electromagnets must be secure, and be
laid so that they are adequately protected from mechanical damage.
Observe the applicable accident prevention and safety regulations for
electrical devices!