Download Print this page
Burkert 0283 Operating Instructions Manual

Burkert 0283 Operating Instructions Manual

2/2-way solenoid valve

Advertisement

Quick Links

Type 0283, 0293
2/2-way solenoid valve
2/2-Wege-Magnetventil
Électrovanne 2/2 voies
Operating Instructions
Bedienungsanleitung
Manuel d'utilisation

Advertisement

loading
Need help?

Need help?

Do you have a question about the 0283 and is the answer not in the manual?

Questions and answers

Summary of Contents for Burkert 0283

  • Page 1 Type 0283, 0293 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d‘utilisation...
  • Page 2: Table Of Contents

    ▶ Keep the instructions in a location where they are available to Basic Safety Instructions ............3 every user. Technical Data ................4 ▶ The liability and warranty for Type 0283, 0293 are void if the operating instructions are not followed. Installation ................8 Maintenance, Troubleshooting ..........10 Symbols ▶...
  • Page 3: Intended Use

    ▶ Keep the device away from highly flammable substances and proper storage, transportation, installation and operation. ▶ Use the device only as intended. media and do not touch with bare hands. Definitions of terms The term "device" always refers to the solenoid valve Type 0283 or Type 0293. english...
  • Page 4: Technical Data

    Conformity Sticking core causes coil to overheat, resulting in a malfunction. Type 0283 and Type 0293 conforms with the EU Directives ▶ Monitor process to ensure function is in perfect working according to the EU Declaration of Conformity (if applicable).
  • Page 5 Oil and grease-free media, e.g. hot water DIN EN 60529 / IEC 60529. 0293 Valve group 2, Class B: Type 0283 and type 0293: Cable plug e.g. Bürkert Type 2508 Fuel gases of the 1st, 2nd and 3rd gas family english...
  • Page 6 Note the voltage and current type as specified on the rating Seal Permitted ambient Type Permitted media material temperature plate. –10...+90 °C Connection: Type 0283 and type 0293: 0283 0...+100 °C max. 55 °C DIN EN 175301-803 Form A EPDM –30...+100 °C for cable plug Type 2508 0293 –15...+80 °C –15...+60 °C...
  • Page 7 Intermittent operation for version with high-performance Operating mode Long-term operation Long-term electronics AC/DC (according to operation Intermittent duty DIN VDE 0580) Characteristic values (according to DIN VDE 0580) (Determination of the per- Intermittent duty mitted operating param- – Cycle time [s] = eters see –...
  • Page 8: Installation

    INSTALLATION Permitted operating parameters Safety instructions DANGER! Risk of injury from high pressure in the system/device. ▶ Before working on the system or device, switch off the pres- sure and vent/drain lines. Switching frequency Risk of injury due to electrical shock. ▶...
  • Page 9 Installation can be in any position, preferably actuator upright. → Before installation, clean any possible dirt off the pipelines. → For Type 0283 install a strainer (≤ 500 µm) upstream of the valve inlet. Type 0293 DN20 already has the strainer integrated Identification for flow in the valve.
  • Page 10: Maintenance, Troubleshooting

    5.3 Electrical installation MAINTENANCE, TROUBLESHOOTING DANGER! WARNING! Risk of injury from high pressure in the system/device. Danger of electrical shock if the protective conductor contact ▶ Before working on the system or device, switch off the pres- between the coil and housing is missing. sure and vent/drain lines.
  • Page 11: Spare Parts

    • the voltage and pressure have been switched on, The following spare parts or spare parts sets are available for the • the pipelines are clean. solenoid valve Type 0283: • Coil If the magnet does not pick up, ensure that: •...
  • Page 12: Transport, Storage, Disposal

    ▶ Observe applicable regulations on disposal and the Seal set environment. SET 2 ▶ Dispose of the device and packaging in an environmentally friendly manner. Housing Fig. 7: Overview of replacement spare parts solenoid valve Type 0283 english...
  • Page 13 Fax + 49 (0) 7940 - 10 91 448 E-mail: info@burkert.com International address www.burkert.com Manuals and data sheets on the Internet: www.burkert.com Bedienungsanleitungen und Datenblätter im Internet: www.buerkert.de Manuels d'utilisation et fiches techniques sur Internet : www.buerkert.fr © Bürkert Werke GmbH & Co. KG, 2010 - 2018 Operating Instructions 1807/09_EU-ml_00805786 / Original DE www.burkert.com...

This manual is also suitable for:

0293