Burkert 0287 Operating Instructions Manual

Burkert 0287 Operating Instructions Manual

2/2-way solenoid valve, stackable

Advertisement

Quick Links

Type 0287
2/2-way solenoid valve, stackable
2/2-Wege-Magnetventil, anreihbar
Électrovanne 2/2 voies, juxtaposable
Operating Instructions
Bedienungsanleitung
Manuel d'utilisation

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 0287 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Burkert 0287

  • Page 1 Type 0287 2/2-way solenoid valve, stackable 2/2-Wege-Magnetventil, anreihbar Électrovanne 2/2 voies, juxtaposable Operating Instructions Bedienungsanleitung Manuel d‘utilisation...
  • Page 2: Intended Use

    OPERATING INSTRUCTIONS INTENDED USE Incorrect use of the solenoid valve Type 0287 can be dangerous The operating instructions contain important information. to people, nearby equipment and the environment. ▶ Read the operating instructions carefully and follow the safety instruc- ▶ The device is designed to control, shut off and meter neutral media up tions in particular, and also observe the operating conditions.
  • Page 3: Basic Safety Instructions

    BASIC SAFETY INSTRUCTIONS Risk of injury due to malfunction of valves with alternating current (AC)! These safety instructions do not make allowance for any contingencies and events which may arise during installation, operation and maintenance. Sticking core causes coil to overheat, resulting in a malfunction. ▶...
  • Page 4: Warranty

    • Distributor (1 input, 2-10 Collector 3.2 Information on the internet outputs) The operating instructions for type 0287 can be found on the internet at: Distributor • Collector (1 output, 2-10 inputs) www.burkert.com Type 0287 •...
  • Page 5 4.2 Block assembly Pos. Description Pos. Description The following drawing shows in an example the components which belong 2 Pull rods Partition wall with O-ring to a block and the place where the accessories can be used. Dummy plate or connection SV module with or without without Quad ring adapter...
  • Page 6: Technical Data

    TECHNICAL DATA 5.2 Application conditions Ambient temperature: max. +55 °C 5.1 Operating conditions Permitted medium temperature depending on seal material: The following values are indicated on the type label: Seal material Permitted medium temperature • Voltage (Tolerance ± 10 %) / Current type 0 ...
  • Page 7 Electrical operating conditions Intermittent operation for version with high-performance electronics AC/DC With high-performance elec- Without electronics Characteristic values (according to DIN VDE 0580) tronics AC/DC 50 Hz, 60 Hz Ambient temper- max. +70 °C max. +55 °C – Cycle time ature (intermittent –...
  • Page 8 Service life: High switching frequency and high pressures reduce the service life 5.3 Conformity In accordance with the EC Declaration of conformity, Type 0287 is com- pliant with the EC Directives. 5.4 Standards Switching frequency The applied standards, which verify conformity with the EC Directives,...
  • Page 9: Type Label

    Body material ▶ Before loosening the pipes and valves, turn off the pressure and vent Type the lines. 0287 A 13,0 NBR Risk of injury due to electrical shock! G1/2 P N 0.5 - 10 bar Connection thread, Operating 24 V 50-60 Hz 5W ▶...
  • Page 10: Before Installation

    6.2 Before installation Devices with solder connection: Installation position: any, actuator preferably upwards. NOTE! Procedure: Danger of overheating! → Check pipelines for dirt and clean. • During the soldering process disconnect the solder connections → Install a dirt filter before the valve inlet (≤ 400 µm). from the valve.
  • Page 11 Procedure: 6.5 Manual control HA15, optional → Tighten cable plug (e.g. Type 2508 or other suitable cable plug), To control the valve manually, turn the rotary knob using a screwdriver observing max. torque 1 Nm. into the vertical position. → Check that seal is fitted correctly.
  • Page 12: Maintenance & Troubleshooting

    MAINTENANCE, TROUBLESHOOTING 7.2 Malfunctions If malfunctions occur, check whether: 7.1 Safety instructions • the device has been installed according to the instructions, DANGER! • the electrical and fluid connections are correct, Risk of injury from high pressure in the equipment! •...
  • Page 13: Overview Of Spare Parts

    ▶ Use only original accessories and original spare parts from Bürkert. 8.1 Ordering spare parts The following spare parts are available for the solenoid valve Type 0287: • Coil set (Pos. 1) • Wearing parts set (Pos. 2 and Pos. 3) Order the coil set or wearing parts set quoting the identification number of the device.
  • Page 14: Transport, Storage, Disposal

    TRANSPORT, STORAGE, DISPOSAL MT08 core membrane HA15 with manual control coupling with O-ring NOTE! Transport damages! Inadequately protected equipment may be damaged during transport. • During transportation protect the device against wet and dirt in shock-resistant packaging. • Avoid exceeding or dropping below the allowable storage temperature.
  • Page 15 Tel. + 49 (0) 7940 - 10 91 111 Fax + 49 (0) 7940 - 10 91 448 E-mail: info@de.buerkert.com International address www.burkert.com Manuals and data sheets on the Internet: www.burkert.com Bedienungsanleitungen und Datenblätter im Internet: www.buerkert.de Manuel d'utilisation et fiches techniques sur Internet : www.buerkert.fr www.burkert.com...

Table of Contents