OPERATING INSTRUCTIONS INTENDED USE The operating instructions contain important information. Incorrect use of the solenoid valve Type 0290 can be dangerous ▶ Read the operating instructions carefully and follow the safety to people, nearby equipment and the environment. instructions in particular, and also observe the operating ▶...
2.2 Approvals Risk of electric shock. Devices which bear the type approval mark were approved at the Kraft- ▶ Before reaching into the 0290, switch off the power supply and secure to prevent reactivation. fahrtbundesamt under the type approval number ▶...
▶ The device may only be used in the explosion-protected area if an The operating instructions and data sheets for type 0290 can be found appropriate additional identification is attached to the type label. → Type 0290 on the internet at: www.burkert.com...
Page 5
Permitted medium temperature depending on seal material and Operating principle 2/2-way valve: coil model: 2 (A) 2/2-way valve, Seal material Model with High-power Model without elec- (NC) direct-acting, normal output A coil or rectifier AC/DC* tronics 50 Hz, 60 Hz* unloaded 1 (P) -10...+80 °C...
Page 6
Permitted media depending on seal material: Electrical operating conditions With high-performance elec- Without Seal material Permitted media tronics AC/DC electronics Neutral media, compressed air, water, hydraulic oil 50 Hz, 60 Hz Per-solutions, hot oils Ambient tem- max. +70 °C max. +55 °C EPDM Oil and grease-free media e.g.
Page 7
Intermittent operation for version with high-performance electronics Permitted operating parameters AC/DC Characteristic values (according to DIN VDE 0580) – Cycle time – Duty cycle – De-energized pause ED – Relative duty cycle SH – Switching frequency Switching frequency 6/min [s] = 10/min 15/min ED[%]...
Type 0290 A 20,0 FKM VA 4.2 Conformity Port connection, G 3/4 P N 0 - 16 bar In accordance with the EU Declaration of conformity, Type 0290 is com- 230 V 50 Hz 16 W pressure range pliant with the EU Directives (if applicable).
INSTALLATION 5.2 Before installation Installation position: Installation can be in any position. 5.1 Safety instructions Preferably: Actuator upright. DANGER! → Prior to installation check pipelines for dirt and, if required, clean. Dirt filter: To ensure that the solenoid valve Risk of injury from high pressure in the equipment. functions reliably, a dirt filter (≤...
NOTE! WARNING! Caution risk of breakage. Danger of electrical shock if the protective conductor contact • Do not use the coil as a lever arm. between the coil and body is missing. ▶ Always connect protective conductor. → Observe direction of flow: ▶...
MAINTENANCE, TROUBLESHOOTING Seal 6.1 Safety instructions Authorized cable plug e.g. Type 2508 or other suitable DANGER! cable plug in accordance with DIN EN 175301-803 Form A Risk of injury from high pressure in the equipment. ▶ Before loosening the lines and valves, turn off the pressure and max.
6.2 Malfunctions SPARE PARTS If malfunctions occur, check whether: CAUTION! • the device has been installed according to the instructions, Risk of injury and/or damage by the use of incorrect parts. • the electrical and fluid connections are correct, Incorrect accessories and unsuitable spare parts may cause injuries and •...
7.2 Overview of replacement spare sets PACKAGING, TRANSPORT, SET 1 = coil set STORAGE, DISPOSAL SET 3 = wearing parts set NOTE! DN 32, DN 40, DN 12 DN 20, DN 25 Transport damages. DN 50, DN 65 Inadequately protected equipment may be damaged during transport.
Need help?
Do you have a question about the 0290 and is the answer not in the manual?
Questions and answers