NETRONIX
Other commands
5.14.
Remote reset of reader
5.14.1.
Command frame:
Header C_Reset
Where:
Parameter name
C_Reset
Response frame:
Header C_Reset +1
Reading-out the reader software
5.14.2.
Command frame:
Header C_FirmwareVersion
Where:
Parameter name
C_FirmwareVersion
Response frame:
Header C_FirmwareVersion+1 Data1.....n
Where:
Data1...n is sequence of dots, which are written as an ASCII codes.
Change buzzer volume
5.14.3.
Use this command to set and store setting in EEPROM memory.
Command frame:
Header C_BuzzerConfig
Gdzie:
Parameter name
C_BuzzerConfig
volume
Response frame:
Header C_BuzzerConfig+1
NETRONIX
Parameter description
Remote reader reset
Parameter description
Read-out of reader software version
volume
Parameter description
Buzzer volume value
CTU-Mxx
CRC
Value range
0xd0
OperationCode CRC
CRC
Value range
0xfe
OperationCode CRC
CRC
Value range
0xD8
0x00-0x0a
OperationCode CRC
.
37