Managing the events

5.12.
The CTU-MxxM series readers has equipped with event memory of capacity
4400 records. Reason of event can be operation related to card or state changing on
reader outputs. The readers does not have RTC clock with battery back-up. After
supply failure, clock is reset to defaults: date: 1 January 2000, time: 00:00:00. Event
counter is not reset.

Setting the event recorder

5.12.1.
Command frame:
Header C_SetEventTrig
Wherein:
Parameter name
C_SetEventTrig
0x7C
CardTrig
In1Trig-In4Trig
Response frame:
Header C_SetEventTrig+1
Masking byte of events related to card
Bit 8
Bit 7
Reserve
Out of
memory
E.g. byte 0x25(00100101) means that events will be written in case of:
inside base card has been red-out,
card written as master has been written,
inside base card has been removed
Masking bytes related to inputs state change
Byte
Bit 8
IO1Trig
IO[3]F
IO[3]R
Bits IO[n]R denote reaction to the input n positive slope,
Bits IO[n]F denote reaction to the input n negative slope
NETRONIX
CardTrig, IO1Trig
Parameter description
Setting the event masking
Masking the events related to card
(see below)
Masking the events related to inputs
(see below)
Bit 6
Bit 5
Card
Card
Reserve
removal
adding
Bit 7
Bit 6
Bit 5
IO[2]F
IO[2]R
OperationCode CRC
Bit 4
Bit 3
Master
card
base card
Bit 4
Bit 3
IO[1]F
IO[1]R
CTU-Mxx
CRC
Value range
0x7C
0x00 - 0xFF
0x00-0xFF
Bit 2
Bit 1
Outside
Inside
base
card
Bit 2
Bit 1
IO[0]F
IO[0]R
.