NETRONIX
Data1...n
Logic Zero, which terminates a
0x00
Response frame:
Header C_LoginUser +1
Changing the password
5.8.2.
Command frame:
Header C_ChangeLoginUser Data1...n, 0x0
Where:
Parameter name
C_ChangeLoginUser
Data1...n
0x00
If =0x00, a reader will not be protected by password. At any moment, there is possible
to set new password later on, to protect the reader by it.
Response frame:
Header C_ChangeLoginUser+1
Logging out of the reader
5.8.3.
This command sets latest password as an invalid.
Command frame:
Header C_LogoutUser
Parameter name
C_LogoutUser
Response frame:
Header C_LogoutUser +1
NETRONIX
This is any byte string
string.
Parameter description
Password change
This is any byte string, which will form
valid access password.
Logic Zero, which terminates a string.
Parameter description
Logging out of the reader.
Any from range: 0x01...0xff.
String length, which can be 0 to
8 bytes
0x00
OperationCode CRC
Value range
0xb4
Any from range:
0x01...0xff.
String length, which
can be 0 to 8 bytes
0x00
OperationCode CRC
Value range
0xd6
OperationCode CRC
CTU-Mxx
CRC
CRC
.
26