Copying The Content Of Transponder Block Into Other Block; Writing The Page Content Into Mifare Ul - Netronix CTU-M Series Technical Data Sheet

Rfid reader
Table of Contents

Advertisement

NETRONIX

Copying the content of transponder block into other block

5.6.7.
Command frame:
Header
C_CopyBlock
Where:
Parameter name
Parameter description
Copying
C_CopyBlock
transponder block into other
block
SourceBlockNo
Source block
TargetBlockNo
Target block for data
Response frame:
Header
C_CopyBlock +1

Writing the page content into Mifare UL

5.6.8.
Command frame:
Header
C_WritePage4B
Where:
Parameter name
C_WritePage4B
PageAdr
Data1...4
Response frame:
Header
C_WritePage4B +1
NETRONIX
SourceBlockNo, TargetBlockNo
the
content
PageAdr, Data1...4
Parameter description
Writing the page content into Mifare UL
Page number in transponder
Data, which are to be written
Value range
of
0x60
**Sector and block numeration
OperationCode CRC
Value range
0x26
0x00...0x0f
whichever
OperationCode CRC
CTU-Mxx
CRC
CRC
.