Logging By Means Of Dynamic Key Buffer To Selected Sector Of Transponder; Logging By Means Of Static Key Buffer To Selected Sector Of Transponder - Netronix CTU-M Series Technical Data Sheet

Rfid reader
Table of Contents

Advertisement

NETRONIX
Logging by means of Dynamic Key Buffer to selected sector of
5.6.3.
transponder
To complete logging successfully, it is important after any input of the reader, to reload
the Dynamic Key Buffer.
Command frame:
Header
C_LoginWithDKB
Where:
Parameter name Parameter description
C_LoginWithDKB Logging to sector
Transponder sector number, to
SectorNo
which user wants to login.
Key type, which is inside internal
KeyType
Dynamic Key Buffer.
DKNo
Dynamic key number
Response frame:
Header
C_LoginWithDKB +1
Logging by means of Static Key Buffer to selected sector of
5.6.4.
transponder
To complete logging successfully, it is important to load Static Key Buffer first.
Command frame:
Header
C_LoginWithSKB
Where:
Parmeter name
Parameter description
C_LoginWithSKB Logging to sector
Transponder
SectorNo
which user wants to login.
Key type, which is inside internal
KeyType
Static Key Buffer.
SKNo
Static Key number
Response frame:
Header
C_LoginWithSKB +1
NETRONIX
SectorNo, KeyType, DKNo
SectorNo, KeyType, SKNo
sector number,
Value range
0x18
0x00 – 0x0f (s50)
0x00 – 0x27 (s70)
0xAA – key of A type
0xBB – key of B type
0x00
OperationCode CRC
Value range
0x1a
to
0x00 – 0x0f (s50)
0x00 – 0x27 (s70)
0xAA – key of A type
0xBB – key of B type
0x00...0x1F
OperationCode CRC
CTU-Mxx
CRC
CRC
.
16