3.0 Power Test

3.1. Plug in the CyberData device and monitor the LED activity above the
ethernet port on the back of the device. See the following figure:
3.2. The green Link/Activity LED blinks off once during the boot up process
when the device begins DHCP addressing and autoprovisioning attempts,
and then comes on again and remains constant (solid green). The amber
100Mb Link LED may be blinking depending on the network activity.
During the initialization process, the Call Button LED should come on solid.
It will then blink 10 times per second until it can find a network address and
attempt autoprovisioning. This can take from 5 to 60 seconds. When the
device has completed initialization, the Call Button LED will remain solid.
Note The default DHCP addressing timeout is 60 seconds. The device will
attempt DHCP addressing 12 times with a 3 second delay between tries
and eventually fall back to the programmed static IP address (by default
10.10.10.10) if DHCP addressing fails. The DHCP Timeout is configurable
in the device's Network settings.
3.3. When the device has completed the initialization process, quickly press and
release the RTFM switch (SW1 button) to announce the IP address.
This concludes the power test. Go to
Configuration File
Quick Start Guide
Retrieval".