Safety Devices - Rinnai LS Series Operation Manual

Table of Contents

Advertisement

A dedicated 240V earthed 10 Amp power point MUST BE USED with this appliance.
DO NOT use power boards or double adaptors to operate this appliance. The heater MUST NOT be located
below a power socket-outlet.
DO NOT unplug the heater while it is in operation or while the fan is still cycling.
DO NOT place containers of liquid above the heater. Water spillage can cause extensive damage to the appliance
and create an electrocution hazard.
DO NOT place articles on or against this appliance.
DO NOT connect to an LPG gas cylinder indoors.
Turn the heater 'OFF' after use.

SAFETY DEVICES

Initial start-up
This heater has a one-time start up cycle. Should there be a fault in the heater no more than 5 manual restarts
should be attempted. If the heater still fails to operate a service call will be required. Refer to the "CARE AND
MAINTENANCE" pages; 13 through 15 for further information.
Over Heat Thermistor
Should the heater get too hot during operation, (for example when the air outlet louvres are blocked), this device
will automatically turn the gas off and allow the heater to be manually restarted, (automatic re-start will not occur).
Refer to the "CARE AND MAINTENANCE" pages; 13 through 15 for further information.
Over heat Thermal Fuse
In the unlikely event of the Over Heat Thermistor failing or some other fault occurring the Over Heat Thermal
fuse will operate completely shutting the appliance down. This device is a 'one hit' only function, a service call will
be required to reinstate operational ability to your heater. Refer to the "CARE AND MAINTENANCE" pages; 13
through 15 for further information.
Power Failure
Refer to page 10. In the event of power failure or power disruption your heater will shut down completely, manual
restarting will be required. Refer to the "CARE AND MAINTENANCE" pages; 13 through 15 for further information.
Electric fuse
The electrical circuits are protected by a fuse. Refer to the "CARE AND MAINTENANCE" pages; 13 through 15
for further information.
Flame Failure Sensing System
These devices within the appliance automatically cut of the gas supply to the burners in the event of a flame failure.
Refer to the "CARE AND MAINTENANCE" pages; 13 through 15 for further information.
Pressure Relief
The burner box glass panel is secured to the burner box via spring loaded pressure relief fasteners.
Rinnai
WARNINGS & IMPORTANT INFORMATION
7
RHFE0800_1000_1500 OM