Unassigning a global spare drive
Procedure
1. From the System Utilities screen, select System Configuration > HPE Smart Array P824i-p MR
Gen10 > Main Menu > Drive Management .
2. In the Drive Management screen, select the spare drive that you want to unassign.
3. In the drive screen, select Unassign Global Spare Drive from the Operation drop-down menu.
4. Click Go.
The Success screen appears to confirm that the operation completed successfully.
5. Review the warning message and click Confirm and Yes to proceed.
Sanitizing an Unconfigured Good drive
WARNING: During a sanitize operation, any data on the drive is permanently lost.
Procedure
1. From the System Utilities screen, select System Configuration > HPE Smart Array P824i-p MR
Gen10 > Main Menu > Drive Management .
2. In the Drive Management screen, select the Unconfigured Good drive that you want to sanitize.
3. In the drive screen, select Sanitize from the Operation drop-down menu.
4. Select one of the options from the Sanitize Type drop-down menu.
5. Select one of the following options from the Unrestricted Sanitize Exit drop-down menu:
•
Enabled - the sanitize operation is performed in unrestricted completion mode.
•
Disabled - the sanitize operation is performed in restricted completion mode.
6. Click Go.
7. Review the warning message and click Confirm and Yes to proceed.
Configuration
57