For more information, see Advanced Controller Management.
4. Click Advanced Controller Properties to configure advanced controller settings.
Advanced controller management
Clearing controller events
Procedure
1. From the System Utilities screen, select System Configuration > HPE Smart Array P824i-p MR
Gen10 > Main Menu > Controller Management.
2. In the Controller Management screen, select Advanced Controller Management.
3. In the Advanced Controller Management screen, select Clear Controller Events.
The Success screen appears to notify that the operation has completed successfully.
Saving controller events
Procedure
1. From the System Utilities screen, select System Configuration > HPE Smart Array P824i-p MR
Gen10 > Main Menu > Controller Management.
2. In the Controller Management screen, select Advanced Controller Management.
3. In the Advanced Controller Management screen, select Save Controller Events.
4. In the Save Controller Events screen, select the file system for saving the logs.
5. Select the directory to save the logs.
The root directory is selected by default.
6. Specify a filename, with a .txt file extension.
7. Click Save Events.
The Success screen appears to notify that the operation has completed successfully.
Saving a serial log
Procedure
1. From the System Utilities screen, select System Configuration > HPE Smart Array P824i-p MR
Gen10 > Main Menu > Controller Management.
2. In the Controller Management screen, select Advanced Controller Management.
3. In the Advanced Controller Management screen, select Save Serial Log.
4. In the Save Serial Log screen, select the file system for saving the serial log.
5. Select the directory for saving the log.
The current directory is the default directory.
6. Specify the filename for the log, using a .txt file extension.
7. Select the number of entries (in KB) to save in the log.
8. Click Save Log.