3.7 clear alert

Clears the current alert condition for the modem dial-out.
This command will cause the Server Management CLI on this platform to stop paging the remote
operator through the modem. However, it does not prevent server management from issuing
alerts to other platform's. If the alert for modem dial-out is not cleared, the Server Management
CLI will continue to page the remote operator every 30 minutes. If the sending of alert messages
is disabled, the triggering of alerts continues to occur, but nothing will be sent over the modem.
Also, the most recent alert is logged as the alert type. If the system is in secure mode (via the
Operator Control Panel keyswitch), the sending of alerts is still allowed, even through remote
access into the system is not.
Syntax
clear alert
Arguments
None
Options
None
Examples
This command removes any pending interrupts and allows the capturing of subsequent alert
conditions. The command returns one of two messages depending on whether or not an alert
is currently pending.
1. With no alerts pending.
MBM> clear alert
No alert pending
MBM>
2. With alerts pending.
MBM> clear alert
Pending alert cleared
MBM>
See Also
enable alert, test alert
Commands