5.6

OPERATING ELEMENTS

5.6.1 PRESSURE REGULATOR UNIT

Designation
1 Pressure regulator - pump
2 Ball valve
3 Pressure gauge - pump
4 Pressure gauge - AirCoat air
5 Compressed air inlet
6 Pressure regulator - AirCoat air
7 Safety and motor pressure relief
valve
Ball valve positions:

5.6.2 RETURN VALVE

Installing a return valve is absolutely necessary for carrying
out a complete depressurization of the pump (see Chapter
7.4).
The suitable return valves (ball valves), return pipes and
hoses for the device can be found in the accessories list.
Designation
1 Product outlet
3 Material return line
4 Return valve
ORDER NUMBER 2351778
3
2
1
6
1
2
C_HE_00018
4
5
B_06915
Designation
1 Open: working position
2 Closed:
The air motor can still be under pressure.
1
4
EvoMotion 40-15 S-HE
EvoMotion 20-30 S-HE
2
7
C_HE_00012