8.2.5 FILLING THE EMPTY PUMP

WARNING
Gas mixtures can explode if there is an incompletely filled pump!
Danger to life from flying parts.
Ignition of potentially explosive surrounding atmosphere.
Fill the device slowly and in a controlled manner.
Avoid potentially explosive atmosphere in the surroundings.
1. Visual check: personal safety equipment,
grounding and all devices ready to use.
2. Place an empty, grounded collection tank (5) under
the return tube (4).
3. Place working material into the tank (6).
4. Close pressure regulator (1) (0 MPa; 0 bar; 0 psi).
5. Open return valve (3).
6. Slowly open the ball valve (2).
7. Slowly turn the air pressure up on the pressure
regulator (1) and only until the pump is running
normally (approx. 0–0.05 MPa; 0–0.5 bar; 0–7.25
psi).
Be ready to switch from air to working material and
prevent back spray.
8. Close ball valve (2) as soon as pure working
material starts coming from the return tube (4).
9. Close return valve (3).
10. Point the spray gun (9), without nozzle, into tank
(5) and pull the trigger.
11. Slowly open the ball valve (2). Be ready to switch
from air to working material and prevent back
spray.
12. As soon as pure working material without air
bubbles is flowing, close the ball valve (2).
13. Close and secure the spray gun.
14. Depressurization in accordance with Chapter 7.4.
15. Dispose of the contents of the tank (5) according to
the local regulations.
ORDER NUMBER 2351778