Hide thumbs Also See for C26 PRO Series:

Advertisement

1
CONVENTIONS
2
CONFORMITY
The C26 PRO series PRO-M radio remote control is in conformity with the
R&TTE 99/05/EC Directive and its essential requirements.
The radio remote control is also in conformity with the norms given in the EC confor-
mity declaration that is included in this manual.
In Technical Data (see chapter 14) there are the characteristics of safety functions
according with EN 954-1.
As required by the Machines Directive and relative harmonised standards, all machi-
nes must undergo a risk analysis; therefore it is necessary to evaluate, within the li-
mits of this analysis, if the machine can be radio remote controlled.
The machine producer and/or the person who decides upon radio remote control use
and installation is responsible for this analysis.
Autec cannot be held responsible if the risk analysis is not carried out cor-
rectly and if the radio remote control is installed on applications that are dif-
ferent from those permitted:
To guarantee correct radio remote control operation, all current regulations regarding
safety at work and accident prevention should be respected. All current user country
national laws regarding the use of both the machine and the radio remote control
MUST ALWAYS be respected.
Autec cannot be held responsible if the radio remote control is used in un-
lawful working conditions.
LIPROMU2-01
Any pieces of text written in bold should be read very carefully.
This symbol highlights extremely important indications and information whi-
ch, if not observed, can create seriously dangerous situations for people,
equipment or property.
This symbol highlights all important indications and information that deal
with operation.
It should be remembered that in some countries rules which control
the use and/or possession of a radio remote control must be res-
pected (see the enclosed "Limitations & Authorisations").
Some national limitations may be present for the use of frequencies
which have not yet been harmonised in European countries. Before
using the radio remote control, verify that it works in a frequency
band which is allowed by national radiocommunication laws.
PERMITTED APPLICATIONS:
Hoisting and moving machines installed exclusively on vehicles that
use a
battery as electrical power supply source (for example:
hydraulic cranes, concrete pumps . . .)
FORBIDDEN APPLICATIONS
- machines installed in areas where equipment with explosion-proof
characteristics are being used
- AC supplied machines
- machines using a DC supply that does not come from a battery
- machines where risk analysis regarding verification of radio remo-
te control conformity to the application is not possible or has given
a negative or uncertain result.
- 17 -
English

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C26 PRO Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AUTEC C26 PRO Series

  • Page 1 This symbol highlights all important indications and information that deal with operation. CONFORMITY The C26 PRO series PRO-M radio remote control is in conformity with the R&TTE 99/05/EC Directive and its essential requirements. The radio remote control is also in conformity with the norms given in the EC confor- mity declaration that is included in this manual.
  • Page 2: Radio Remote Control Description

    RADIO REMOTE CONTROL DESCRIPTION Industrial radio remote controls are used to command machines from a distance. Each in- dustrial radio remote control is made up of a portable transmitting unit, from which the user can remotely control the machine, and a recei- ving unit installed on board the machine itself.
  • Page 3 SAFETY contact. Example of wiring Proportional Autec supplies the radio remote control with the proportional ou- output tput values already set depending on type of valves. During instal- setting lation, these values must be verified and, if necessary, modified according to how the machine is to user’s working preference (see...
  • Page 4: Warnings Regarding Use

    - are qualified and trained, - know the "radio remote control + machine" system well. Autec cannot be held responsible if the radio remote control is in- stalled on applications other than those permitted and if used in ir- regular working conditions.
  • Page 5 According to the indications given in this manual, routine mainte- nance is fundamental for using the radio remote control safely. After each maintenance procedure, always make sure that only the expected manoeuvres are carried out when the relative commands are sent by the transmitting unit. Prescriptions summary The prescriptions that follow should be considered as the minimum necessary for safe...
  • Page 6: Warnings Regarding Special Maintenance

    Follow the instructions and warnings given by the machine producer regar- ding the machine controlled by the radio remote control. If this manual is lost or damaged, ask for a copy from Autec. Please specify the serial number of the relative radio remote control.
  • Page 7: Transmitting Unit And How It Works

    The information contained in this manual is subject to modification without notice and is not binding. No parts of this manual may be reproduced by any means without the written per- mission of Autec (including recording and photocopying). Certificate of guarantee The conditions of the radio remote control guarantee are given in the "Certificate of...
  • Page 8 - the battery is not charged enough and/or - the radio remote control has not been used for 3 and a half minutes (to deactivate automatic switching off, please contact Autec authorised personnel). Recharging the battery Remove the battery from the transmitting unit and insert in the battery charger.
  • Page 9: Receiving Unit

    Once the battery is fully charged, the "END OF CHARGE" light will illuminate. Battery charging should be performed at an ambient temperature within the range +5°C to +45°C. See the supplied booklet for all instructions, warnings and technical data regarding the batteries and the battery changer. RECEIVING UNIT POWER light antenna...
  • Page 10: Proportional Output Setting Procedure (Remote Set Up)

    SAFETY The radio remote control is equipped with a safety function called SAFETY which pro- tects the system from involuntary movements caused by possible radio remote con- trol faults. This function constantly controls the rest position (neutral) of the movement actua- tors in the transmitting unit and is available on the receiving unit SAFETY relay ou- tput.
  • Page 11 To reset the initial proportional output values (i.e. those given in the technical data sheet), with calibration key K1 inserted, just keep reset button P pressed until the green LED L stops flashing and remains lit. To keep the same settings in case of module replacement, move the K2 memory from the old module to the new one.
  • Page 12: Radio Frequencies

    "Frequency change") without having to touch the inside of either the tran- smitting or the receiving units. Manual Only contact Autec authorised personnel if the working radio fre- selection quency has to be set in this manner. Using the radio remote control in the manual selection mode makes it possible to work at a specific frequency.
  • Page 13 STOP diagnostic. pushbutton. If the transmitting unit does not switch on cor- CALL FOR rectly, AUTEC SERVICE Diagnostic of receiving unit Correctly insert Is the connection plug Is the POWER the connection plug between the receiving...
  • Page 14: Technical Data

    TECHNICAL DATA General Frequency range ............433.050 - 434.790 MHz .................... 869.7 - 870 MHz Programmable radio channel (433 MHz) ............64 Programmable radio channel (870 MHz) ............12 Channel spacing ............25 kHz (option 12.5 kHz) Hamming distance ..................Probability of non-recognition of error ............

Table of Contents