LIGHT TOWER SET UP

1. For maximum light coverage, locate the unit at ground level or in a spot higher than the area being illuminated
by the lamps.
The mast extends up to 30 ft (9.14 m). Make sure the area above the unit is open and
clear of overhead wires and obstructions. Do not set up the unit if high winds or
storms capable of producing lightning are expected in the area.
E
D
B
C
D
2. Place the unit on firm ground that is relatively flat, then block the wheels to keep it from moving (A). This will
make it easier to level the unit.
3. Pull the locking pin on the tongue jack and rotate the jack 90°. Replace the locking pin (B). Turn the jack
handle clockwise to raise the trailer tongue off of the towing vehicle.
4. A grounding stud is located on the frame of the trailer at the base of the mast post (C). For grounding
requirements, follow any local, state, or National Electrical Code (NEC) guidelines.
5. Pull the locking pin (D) on the outrigger (E) and pull each outrigger out until the spring loaded locking pin
snaps back into place. Pull the locking pin on the outrigger jack and rotate each jack 90° so the jack pad is
facing down. Replace the locking pin.
10454 O

Section 3 - Operation

WARNING
H
A
E
G
Figure 6 - Light Tower Set Up
MLT4060-80M/K Operating Manual
J
H
F
DETAIL C
DETAIL D
DETAIL G
DETAIL H
00151
15