Technical Specifications - EV Charging Single Phase Inverter (North America)
INPUT
Maximum DC
Power
Transformer-less,
Ungrounded
Maximum Input
Voltage
Nominal DC Input
Voltage
Maximum Input
Current
Max. Input Short
Circuit Current
Reverse-Polarity
Protection
Ground-Fault
Isolation
Detection
Maximum
Inverter Efficiency
CEC Weighted
Efficiency
Nighttime Power
Consumption
ADDITIONAL FEATURES
Supported
Communication
Interfaces
Revenue Grade
Data, ANSI C12.20
Rapid Shutdown
- NEC 2014 and
2017 690.12
(1) Revenue grade inverter P/N: SExxxxH-US000xxW2.
EV Charging Single Phase Inverter Guide MAN-01-00588-1.1
SE3800H-
SE5000H-
US
US
5900
7750
380
10.5
13.5
RS485, Ethernet, ZigBee (optional), Cellular (Optional)
Automatic Rapid Shutdown upon AC grid disconnect
SE6000H-
SE7600H-
US
US
9300
11800
Yes
480
16.5
20
45
Yes
600 kΩ Sensitivity
99.2
99
< 2.5
(1)
Optional
85
SE11400H-
Unit
US
17650
W
Vdc
400
Vdc
30.5
Adc
Adc
%
%
W